SMC Corporation of America
Elite Part Number Search
Search Results "PSE543A-M3-C2"

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. EtherNet/IPTM communication is not established. Green flashing 4 EtherNet/IPTM communication is established. Green ON NS EtherNet/IPTM communication is time-out. Red flashing Valve plate (EX600-ZMV ) IP address is duplicated. Red ON Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Link, No Activity (100 Mbps) Link, Activity (100 Mbps) Link, No Activity (10 Mbps) Link, Activity (10 Mbps) L/A PORT2 Valve plate (EX600-ZMV#) Refer to the SMC website (URL https://www.smcworld.com) for more information about LED state. Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. M12 4-pin Socket, D-code 4 Configuration Pin No. Signal name The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. Single Flash Safe operational status (Green) ON Operational status 4 OFF No communication error Flash Communication setup error Valve plate (EX600-ZMV ) (Red) Double Flash Communication error (application watchdog timeout) Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 Valve plate (EX600-ZMV ) Safety Instructions (5)Connect the SI unit to the valve manifold. Insert the valve plate into the valve plate mounting groove on the side of the SI unit.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. 4 LED Display 300 g Weight Refer to the product catalogue or SMC website (URL https://www.smcworld.com) for more information about product specifications. Valve plate (EX600-ZMV#) The status display LED displays the power supply and communication status. Safety Instructions (5)Connect the SI unit to the valve manifold.

(M3 x 8) Apply 0.6 to 0.7 Nm tightening torque to the screws. M12 4-pin Socket, D-code 4 Configuration Pin No. Signal name The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

M3 hexagon screw Tightening torque: 0.6 Nm Tie-rod Tightening torque: 0.6 Nm If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.

(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Power supply (0 VDC) 3 6 4 4 3 20 m or less total extension per branch Branch cable length Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

M3 x 18: 2 pcs. (Hexagon socket head cap screw (with spring washer)) CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Solenoid valve or End Plate R (Output Block side) Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Tie-rod: 2 pcs.

M3 x 18: 2 pcs. (Hexagon socket head cap screw (with SW)) : Please refer to the separate catalog regarding assembly and disassembly with other unit. Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Note Hold together so that there is no gap between units and tighten the screws.

-28-C 37104-3101-000FL 1-1473562-4 ZS-28-C-1 37104-3122-000FL ZS-28-C-2 37104-3163-000FL ZS-28-CA-4 2-1473562-4 ZS-28-C-3 37104-3124-000FL ZS-28-C-4 37104-3165-000FL ZS-28-C-5 37104-2206-000FL -12No.PS-OMG0001CN-H PSE31() PSE30() 2 3 1 (DC(+)) (LINE(+)) (DC(+)) 2 3 (DC(-)) (DC(-)) 4 (OUT15 V) (LINE(-)) (OUT420 mA) A A A -13No.PS-OMG0001CN-H DC+5 OUT1 4 OUT2 3 2 DC-1 M3

Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. Turn the power off and turn it on again. System error An internal data error has occurred. Press the UP button continuously to keep increasing the set value.

Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. 2. Press the or button to change the set value. The button is to increase and the button is to decrease the set value. : If the error cannot be reset after the above measures are taken, then please contact SMC.

Flow indicator LED Safety Instructions Square groove Install the product (with bracket) using the M3 screws (4 pcs.). Bracket thickness is approximately 1.2 mm. Power indicator LED Indicates the power supply status. LED is ON (Green) when power is ON. LED is ON (Red) when a system error occurred.

M3 (2 ) (M315 L) 0.320.02 Nm L M315L () M315L L () L () M4 (2 4 ) 1mm (22 ) -14No. PF-OMK0003CN-E 0.320.02 Nm L () L () M4 (2 4 ) 1mm (22 ) -15No. PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No.

They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. 04 Equivalent to M3 (L=6) 20 0.04 to 0.05 Nm 40 Equivalent to M4 (L=10) 0.09 to 0.10 Nm Element Description This unit supplies the fluid from the supply side main piping to the application.

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Heat Differential temp. of 3 oC Differential temp. of 6 oC Radiated Model between inside and outside between inside and outside kW of installation area of installation area HRS012-AApprox. 2 40 20 HRS018-AApprox. 4 70 40 HRS024-A-20 Approx. 5 90 50 The water-refrigerated thermo-cooler discharges heat

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Heat Differential temp. of 3 oC Differential temp. of 6 oC Radiated Model between inside and outside between inside and outside kW of installation area of installation area HRS030-A-20 Approx. 6 100 60 The water-refrigerated thermo-cooler discharges heat by using facility water.

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Differential temp. of 3 oC Heat Differential temp. of 6 oC Radiated between inside and Model between inside and outside kW outside of installation of installation area area HRS040-A-20 Approx.8 120 70 The water-refrigerated thermo-cooler discharges heat by using facility water.