SMC Corporation of America
Elite Part Number Search
Search Results "11-LEFS40S4A-1000"

400 600 800 1000 1200 1400 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 1000 0 200 400 600 800 Flow rate ( /min (ANR)) Relief flow rate ( /min (ANR)) Supply pressure P1 (MPa) 14-5-11 11 Series IR1000/2000/3000 Series IR3000 Flow Characteristics Relief Characteristics Pressure Characteristics Testing methods conform to JIS B 8372.

When the knob is not easily locked, turn it left and right a little and then push it (when the knob is locked, the "orange mark", i.e., the gap will disappear). 0.1 0.1 0 0 0 0 1000 2000 3000 4000 5000 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min (ANR) AR25 Rc 3/8 AR50 Rc 1 0.6 0.6 0.5 0.5 Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 0 500 1000 1500

-/22-CG120 11-/22-CG125 11-/22-CG132 11-/22-CG140 11-/22-CG150 11-/22-CG163 11-/22-CG180 11-/22-CG1100 Non-lube Double acting, Available 20 25 32 40 50 63 80 100 single rod 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note) Consult SMC for long stroke.

Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.

14 18 30.5 37 47 11 14.5 20.5 11 14 18 30.5 37 47 11 14.5 20.5 Note 1) ;in the table indicates the pad material "N, S, U, F, GN, GS."

CSA C22.2 No. 0-M91, CSA C22.2 No. 94-M91, CSA C22.2 No. 142-M1987, CSA C22.2 No. 157-92, CSA C22.2 No. 213-M1987, CSA C22.2 No. 60079-0:11, CSA C22.2 No. 60079-11:11, CSA C22.2 No. 60079-15:12, CSA C22.2 No. 60529:05, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2012, ANSI/ISA 60079-15: 2012, FM 3600 November 1998, FM 3610 October 1999, FM 3611 October 1999, FM 3810-2005, ANSI/ NEMA 250:1991

PTFE (TF) option available for the AP 500, AP, AZ & AK 1000 & 1100 and AZ & AK 1300. The primary application for this material is for pressure regulators inside process tools. [Vespel] Trademark of DuPont Plastic with excellent heat resistance (polyimide resin). This material has excellent heat and wear resistance.

Positioning distance (mm) 1000 500 100 10 1 10 100.5 50.5 10.5 1.5 0.5 100 10.5 5.5 1.5 0.6 0.5 Speed (mm/s) 500 2.7 1.7 0.9 0.6 0.5 1000 1.9 1.4 0.9 0.6 0.5 A B C D Values will vary slightly depending on the operating conditions.

B H C C d d 10 Y-J010B 15.2 8 21 M4 x 0.7 CP95 SNJ-006B 16 Y-J016B 6 NTJ-006A 16.6 11 21 M5 x 0.8 M6 x 1.0 4 8 9.2 6 M3 x 0.5 2.4 5.5 6.4 SNJ-010B 10 NTJ-010A M8 x 1.0 4 11 12.7 10 M4 x 0.7 3.2 7 8.1 NDd9 NDH10 NX R1 U1 Part no.

SOL.A SOL.B 17 16 15 14 2 1 19 Orange Black Station 10 Electrical characteristics 25 24 20 Red White 13 3 SOL.A SOL.B 23 18 Item Property 21 Brown White Station 11 12 4 22 Pink Red 26 Conductor resistance /km, 20C 22 19 65 or less SOL.A SOL.B 11 5 23 Gray Red 21 20 Station 12 10 9 8 7 6 24 Black White M27 female thread Voltage limit V, 1 minute, AC 1000 White None COM. 25 White None COM.

B L2 Q L1 H 1(P) 2(A) L3 L4 L5 L6 C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 41 1.2 26 23 11 3.5 11 M5 M5 M5 18 29.1 16.5 VHK-B1A 29 29.1 44.5 14.5 1 27 22 16.5 26 61.6 58.2 2.0 2.0 54 51 1 8 11 41 8.6 1.2 13 3.5 18 32.6 16.5 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-01S-01S 1 8 1 8 30 32.6 65.2 57 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62

Assuming that the tube I.D. is 2 mm, the piping capacity is as follows: V = p/4 x D2 x L x 1/1000 = p/4 x 22 x 1 x 1/1000 = 0.0031 L (2) Assuming that leakage (QL) during adsorption is 0, find the average suction flow rate to meet the adsorption response time using the formula on page 392.

Value (-32767.. 32767 ) Value x 0.01 (mA or V) 1000 8 Upper Limit Value*1 1: True Generates an error. *1 9 Monitor Lower Limit 0: False Does not generate an error. Generates error per channel when the input value falls below the set value.

Ratio of discharge rate against fresh water (%) PAX PB 50 0 1 10 100 1000 Viscosity (mPas) Caution Viscosities up to 1000 mPas can be used.

(Plug) PA+stroke S G FA FB C+stroke B+stroke A+stroke E MGPM, MGPL/Common Dimensions Standard stroke (mm) Bore (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL P PA PB PW Q GC 59.5 37.5 12 12 16 16 10 10 12 12 48 54 64 78 12.5 12.5 112 120 148 162 24 27 32 39 M8 X 1.25 20 20 22 22 M8 X 1.25 6.6 6.6 8.6 8.6 15 34 38 47 55 16 16 20 20 9 M6 M6 M8 24 27 32 39 11 11 14 14 30 30 40 50 34

Location where vacuum pressure is measured Piping length (m) Vacuum source Adjust the measured vacuum pressure using a regulator to be the value in the graphs below. 0 -0.001 -0.002 -0.003 -0.004 -0.005 -0.006 -0.007 -0.008 -0.009 -0.010 -0.011 -0.012 11-CJ2 11-CM2 11-CQ -0.027 13-MXS16 Vacuum pressure (MPa) Vacuum pressure (MPa) -0.028 13-MJP 13-MXS20 -0.029 11-CU -0.030 13-MXS25 -0.031

Count Pressure characteristics Flow characteristics Supply pressure: 0.2MPa Set pressure: 0.05MPa Relief flow characteristics Supply pressure: 0.2MPa 0.25 1.0 0.15 Output deviation factor (%F.S.) 0.20 0.5 Set pressure (MPa) Set pressure (MPa) 0.10 Set point 0.15 0.0 0.10 0.05 0.5 0.05 1.0 0 500 1000 1500 2000 0.00 0.00 0 500 1000 2000 1500 0.0 0.1 0.2 0.3 Flow rate (l/min (ANR)) Flow rate

LEKFS32 LEKFS40 1000 1000 1000 800 800 800 L1 L1 [mm] L1 [mm] L1 [mm] 600 600 600 X 400 400 400 200 200 200 0 0 0 0 5 10 15 20 25 30 35 0 10 20 30 40 50 60 70 0 10 20 30 40 50 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 Horizontal/Bottom 800 800 800 L2 L2 [mm] L2 [mm] L2 [mm] 600 600 600 Y 400 400 400 Mer m 200 200 200 0 0 0 0 5 10 15 20 25 30 35 0 10 20 30 40 50 0 10 20

Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.

B Cushion Rubber bumper, Air cushion REC 50 to 1000 mm/s 20 to 63 Piston speed 50 to 700 mm/s 80, 100 CX Thread tolerance JIS Class 2 st + 1.4 0 st + 1.5 0 st + 1.4 0 st + 1.5 0 Up to 1000 mm, Up to 1200 mm 20 to 63 CY Stroke length tolerance Up to 1000 mm, Up to 1500 mm 80, 100 Basic style, Axial foot style, Rod side flange style, Head side flange style, Clevis integrated style MQQ M JIS