MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.
Speed [mm/s] 1 1 100 0.49 2 2 200 0.74 3 3 300 0.98 4 4 400 1.23 5 5 500 1.47 6 6 600 1.96 7 7 700 2.45 8 8 800 2.94 9 9 900 3.92 10 10 1000 4.90 Note) The factory default setting for the switch is No.1 (100 mm/s).
SL5201 0.5 to 10 psig (0.0034 to 0.07 MPa) SL5202 0.5 to 30 psig (0.0034 to 0.2 MPa) SL5206 1 to 60 psig (0.007 to 0.4 MPa) SL5210 1 to 100 psig (0.007 to 0.7 MPa) 100 mm Hg absolute to 10 psig (-88kPa to 0.07 MPa) Select compatible materials of construction for the gas Vacuum to 150 psig (1.0 MPa) 500 psig (3.4 MPa) 1000 psig (6.9 MPa) 40 to 160C (40 to 71C) (No freezing) 1) 0.07 2 x 10-11
Refer to "Replacement Actuator (Cylinder)" on page 11 about how to order . 2.
Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric size 4, 6 8, 10 1/8" 5/32" 3/16" 1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min}
Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1
Piping connection type Connection size Piping connection system Size and part no. 1/4 3/8 KK4P-02MS Nil N F Rc NPT G 02 03 11 Port size Screw-in type Plug part no. Note1) With S coupler plug Note 1) In case of a type with an S coupler plug, specify no symbol (Rc) for the piping connection type. The size is Rc 1/4.
Series VQ20/30 Dimensions Plug lead unit manifold (VV2Q22) Equation L1= (n1) X 29+49 L2=L110 L3=L410.5 L5=L111.2 Dotted line: DIN rail mounting (-D) Dimensions n: Station (Max.20) L n 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 310 600 281 571 252 542 223 513 194 484 165 455 136 426 107 397 78 368 L1 L2 L3 L4 L5 49 339 300 590 271 561 242 532 213 503 184 474 155 445 126 416 97 387
M3 3B = M3E/M3E max = 1.8/10 = 0.18 L2 M3E m x g FE From above, n = 1 + 2a + 2b + 3A + 3B = 0.25 + 0.105 + 0.084 + 0.225 + 0.18 = 0.844 From n = 0.844 1, it is applicable. 8-16-10 10 MX MTS MY CY MG CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless cyinder, low profile guide type Nil S n 2 pcs. 1 pc. n pcs
L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. flow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch fitting type Symbol Applicable tubing O.D.
(Refer to page 11 for details.) When compressed air containing ozone (possibly generated from other machinery and equipment present in a plant) enters a pneumatic system, it adversely affects the system's rubber components.
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-REA63 63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.
Description Material Qty. 11 Diaphragm assembly NBR, other P362010-1 1 1 1 1 1 P362020-13 P362020-2 P362020-13 P362020-2 12 Diaphragm assembly NBR, other P362010-2 1 1 1 1 1 P362020-5 P362020-5 P362030-34 P362030-34 13 Diaphragm NBR, other 1 1 P36202019 P36202019 14 Valve Stainless steel, NBR P36201058 1 15 Valve Stainless steel, H-NBR 1 1 P36202068#1 P36202068#1 16 Valve Brass
Required flow rate Recommended flow rate 700 L/min 400 L/min = 1.75 2 elements q Calculating the number of elements Selecting a vessel [Flow rate] (When viscosity rate is equivalent to water) Use the flow rate to calculate the number of elements.
, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 12-REA63 Note 1) Stroke exceeding the standard stroke will be available upon request as special product.
Dimensions Dimensions 4-R2.5 12 25 41.5 17 34 24 R16.5 Panel nut Gasket 26 11 1.5 24 44 Max. panel thickness 4.5mm 5.4 1.6 54 Install the gasket underneath the panel and bracket (bonnet side).
800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25 0.20
After securing the cylinder, readjust the stroke with the adjustment bolt. 80 CY1L Load [N] 70 CY1H 60 15 50 CY1F CY1F 40 30 10 CYP 20 10 0 Adjuster holder 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.