SMC Corporation of America
Elite Part Number Search
Search Results "22-MXQ8L-20C"

Specification: 22 (Copper, Fluorine and Silicon-free + Low Particle Generation, Vacuum Suction Type), Bore: 12mm, Thread: M Thread: ø6 to ø16 Bore; Rc: ø20, ø25 Bore, Symmetric Type: L (Symmetric Type), Stroke: 20mm, Adjuster: C (Metal Stopper, Both Ends), Functional Option: Standard Type, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal

Specification: Copper, Fluorine and Silicon-free + Low Particle Generation, Vacuum Suction Type, Bore: 12mm, Thread: M Thread: ø6 to ø16 Bore; Rc: ø20, ø25 Bore, Symmetric Type: Symmetric Type, Stroke: 20mm, Adjuster: Metal Stopper, Both Ends, Functional Option: Standard Type, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire: -, Number: -

capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] HED V After 15 minutes, cool 32C down to 20C.

Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.

Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.

The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.

Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.

(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.

to 60C (No freezing) Fluorine-based grease AS-D AS-T Note 1) The maximum operating pressure is the value at 20C.

Speed Controller Cylinder Solenoid valve Tubing Silencer Max. return speed (mm/s) 10 20 30 6 ASD230FM CJ2 SYJ500 TU0604 1 m AN11001 10 16 Cylinder size 20 ASD330FM CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 32 Values are measured at 0.5 MPa and 20C.

to 60C (No freezing) Fluorine-based grease AS-D AS-T Note 1) The maximum operating pressure is the value at 20C.

FGF FGH FGH [Test conditions] Fluid: water / Test dust: ACFTD / Flow rate: 35 L/min Dust concentration: 10 mg/L / Temperature: 20C Element: EJ801S Schematic diagram of filtration efficiency data measuring circuit FQ1 EJ-2 m FN 100 99 Dust feeder Initial filtration efficiency (%) EJ-4 m EB ES Tank Flow meter EJ-6 m Differential pressure gauge EJ-13 m 95 Pressure gauge Downstream side sampling

temperature Round lock nut With seal, Round lock nut, Nickel plated Option Weight (g) 181 106 64 29 10 6 3 Flow rate L/min (ANR) 105 230 460 920 1700 20 Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.32 0.7 1.4 2.8 5.2 0.06 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 0.2 Free flow 0.4 0.2 0.3 0.2 0.3 0.4 Note 1) Flow rate values are measured at 0.5 MPa and 20C

The conversion conditions can be switched to 20C and 101.3kPa for the high flow rate types.

(mm) 2 x 1.2 Fluid Air, Water Max. operating pressure (at 20C) 0.8MPa Burst prssure Refer to pressure characteristics curve.

REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM

REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 Air flow (l/min (ANR)) 38 Controlled flow CX 0.2 0.1 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.

Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232