SMC Corporation of America
Elite Part Number Search
Search Results "25A-ISE20A-T-M-M5-JBK"

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A2 (Bracket B, Horizontal Mounting)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: w/o Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: Operation Manual, Calibration Certificate

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids.  Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output. 

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids.  Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output. 

1 3 Port Air Operated Valve Series VPA3145/3165/3185 How to Order SA 04 4 5 1 VPA3 VA Thread type SA VPA Air operated valve Nil Rc G NPT NPTF F N T VA 1 Number of pilot VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size (IN, OUT port) Single Port size Rc

J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.

3 Port Air Operated Valve VPA3145/3165/3185 Series How to Order 04 4 5 1 VPA3 Thread type VPA Air operated valve Nil Rc G NPT NPTF F N T Port size (IN, OUT port) Number of pilot 1 Single Symbol Port size Rc size VPA3145 VPA3165 VPA3185 Body size (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 03 04 1 2 1 4 6 06 10 12 14 20 8 1 2 1 Valve option Nil For ordinary pressure For vacuum and low pressure

5 Port Air Operated Valve Series VPA450/470 How to Order VPA4 1 5 0 10 VP 5 port Air operated valve Thread type Nil Rc G NPT NPTF Function F N T VPA4270-14 2 position single pilot 2 position double pilot 3 position closed center 3 position exhaust center 1 2 3 4 VPA4150-04 Symbol Port size Applicable valve model Port size Note) 3 position is not available on Series VPA470.

NBR/POM A With A Direct piping type 40A 24 VDC 50A A B Direct piping type B C D E F G H J K L M N P Q R S T U V W 65A 5 100 VAC Grommet Flange type with surge voltage suppressor 110 VAC A B C D Direct piping type 200 VAC Flange type 230 VAC 80A 6 Flange body I type 24 VDC Flange body II type 24 VDC DIN terminal with surge voltage suppressor 100 VAC 7 8 90A B Flange type 110 VAC 100A 200