78 91.5 111.5 15 15 20 12 18 25 16 22 25 49 56.5 66 M6 X 1.0 M8 X 1.25 M8 X 1.25 22 26 32 58 54 62 39 46 56 M10 X 1.5 M12 X 1.75 M14 X 2.0 8.6 10.6 12.5 25, 50, 75, 100, 125, 150, 175, 200 (mm) Bore size (mm) OB OL P PA PB PW Q RA RB RC S SA SB T U VA VB WA WB 50, 75, 100st Larger than 100st 25st 50, 75, 100st Larger than 100st 25st 117 128 168 55 74 89 54 56 71 100 125 150 24 24 35 188 225
The calculalion of standard piston speed for kinetic energy at load is ihe average speed x1.2. 225 0 14.s (01) 29 (0.2) 43.5 (0.3) 58 (0.4) e The relation between speed and load is as illustrated below. The range of kinetic energy is under the lineO Al locking. lock-up unit absorbs not only kinetic energy. but also thrust of cvlinder itself.
Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed
Class 3 ground Ground resistor 100 or less Command pulse (MAX.225/kpps) PULS SIGN P Incremental encoder SIGN CLR P Deviation counter clear signal (active high) 2CN PG CLR P Be certain to treat the shielding wire terminals.
Command pulse (maximum 225/kpps) P Class 3 ground Ground resistor 100 or less Incremental encoder P Deviation counter clear signal (active high) 2CN PG P Be sure to treat the shielding wire terminals. +12 to 24V Note) 4.7k 13 14 5mA Servo ON 1Ry 0V SV-ON 1Ry ON for servo ON 2Ry Proportional control (P actuation) Reverse drive suppression 15 P-CON 2Ry ON for proportional control N-LS 16 N-OT
Mounting With Limited Space Options MXW MXS Long Stoke Slide Table Slide Table Good Precision And Ideal For Transfer And Many Options Pressing Applications MXQ MXP Precision Slide Table Compact Slide Table Better Precision Extreme Precision And More Options 4 Versatile Sizes Bore sizes and stroke lengths to provide the movement you need. 5 10 15 20 25 30 40 50 60 75 100 125 150 175 200 225
0 16 25 40 16 25 40 Bore (mm) Bore (mm) MY2C MY1C MY2C MY1C 2 Magnetically Coupled Rodless Cylinder/Low Profile Series CY1F Compact Max. 29% reduction in height (mm) Height Series 10 15 25 CY1F 28 34 46 46 63 CY1H 39.5 CY1H CY1F Short body Max. 31% reduction in overall length Reduction in length is 22% over MY2H cylinder CY1F (mm) Length MY2H Series 25 240 350 310 15 205 294 260 10 198 225
L type plug connector (L) ..i M typ plug connector (M) a , ; ll : with indicator lisht and surge voltage suppressor NW523-42-OOt-B7T 't3.27 (337) (353) Lr 2.56 (65) 3.19 (81) 3.42 (97) 4.45 (1r3) 5.08 029) 5.71 045) 6.34 (16r) 6.97 \177 ) 7.60 (1so) 8.23 (209) 8.86 (225) 9.49 \241) 10.12 (257) 10.75 1273) 11.38 (289) 12.01 (305) 12.U (3a ) La 2.05 (52) 2.64 (68) (84) 3.94 (100) 016) 5.20
385 1800 23 48 82 127 160 230 296 366 It must be noted, however, that oversized piston rods transmit more side load 2400 19 45 75 114 145 213 281 347 than is the case with more flexible smaller rods; therefore, the use of oversized 3200 16 41 67 103 130 194 261 329 4000 13 38 63 94 119 175 240 310 rods should not be considered a remedy against excessive side loads. 5000 9 34 60 87 110 163 225
Prassuro 1s0 PSIG (9.9 Kgflcm ) Prool Pr333ure 225 PSIG (15 Kgr cm ) Amblnl Temp. 40 120"F (5 50"C) Responsg Tlme 30 ms Max. 50 ms Max. 30 ms Max. 50 ms Max, Hysteresls 3% F.S. Repeatablllty 3/. Sensitivity o.5/.
Normally Closed SERIES NVF 110 DIRECTIONAL AIR VALVE DIRECT SOLENOID OPERATED CHARACTEFISTICS Port Sizss (NPTO '10-32 P&E; 10-32 or 1/8"A Opelating Prsssure 0'100 PSI; 0-150 PSI (H) ftoof Pre6sur 225 PSIG (15Kgflcm'z) Operailng Temperature 14-140'F(101o + 6O"C) a;a lnrusn s.6 VA (50 Hz),5.0 VA(60 Hz) Holding 3.4 VA (50 Hz),2.3 VA (60 Hz) PowerConaumptlon DC 1 . 8 W c, 0.055 , 0.05 (H Type
temperature (C) Ambient temperature (C) Pressure dew point (C) Working fluid Inlet air temperature (C) Inlet air pressure (MPa) Ambient temperature (C) 0.7 60 55 32 10 Compressed air 5 to 80 5 to 75 0.15 to 1.0 2 to 40 (Relative humidity of 85% or less) Single phase, 100/100 to 110VAC (50/60Hz) Single phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225
10 1 50 4.2 2.1 1.1 0.3 0.1 50 2.1 4.1 1.1 0.3 0.1 Speed (mm/s) Speed (mm/s) 100 2.1 1.1 0.6 0.2 0.1 100 1.1 2.1 0.6 0.2 0.1 200 1.1 0.6 0.3 0.1 0.1 200 0.6 1.1 0.3 0.1 0.1 For transfer load of 1.5kg Positioning time (sec) Positioning distance (mm) 200 100 50 10 1 50 4.1 2.1 1.1 0.3 0.1 Speed (mm/s) 100 2.1 1.1 0.6 0.2 0.1 200 1.1 0.6 0.3 0.1 0.1 Refer to page 302 for acceleration time. 225
R) A A A P = 19 13.5 L2 L1 4 1 7 8 26 47.5 Approx. 300 (lead wire length) n-Rc(PT) 1/8, M5 x 0.8 (port A) 7 20 34 2-4.5 (bracket mounting holes) 4-M3 x 0.5, depth 6 (bracket mounting screws) 7 8 47.5 15.5 20 25 49 4 L3 7 7 L: Dimension table n: Stations n L 1 35 27 13 2 54 46 32 3 73 65 51 4 92 84 70 5 111 103 89 6 130 122 108 7 149 141 127 8 168 160 146 9 187 179 165 10 206 198 184 11 225
24.1dB 18.1dB 14.5dB 12.0dB 10.1dB 00 01 02 03 2250 1125 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 70 66 62 59 56 53 51 48 46 45 43 41 40 38 37 36 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 17.6 16.5 15.6 14.8 14.1 13.4 12.8 12.2 11.7 11.3 10.8 10.4 10.0 750 562 450 375 321 281 250 225
Pr.46 OPR speed 1 74 75 224 225 374 375 524 525 Pr.47 Creep speed 1 76 77 226 227 376 377 526 527 Pr.48 OPR retry 0:Do not retry OPR with limit switch 0 78 228 378 528 1:Retry OPR with limit switch Pr.50 Setting for the movement amount after near-point dog ON The setting value range differs according to the "Pr.1 Unit setting". 0 80 81 230 231 380 381 530 531 0:Pr.9 Acceleration time 0 0
ADH-E400 1.6MPa 0.051.6MPa 3/h 0.024m 0.7MPa IDF60/70/80/90 Series 10-1 IDX-OM-W093 L 10.3 Rc1/225 30 5 IDF60 2722IDF70IDF80IDF90 22 IDF60 (IDF70/80/90) 1) 2830Nm 2) 10.4 1 1 IDF60/70/80/90 Series 10-2 IDX-OM-W093 R 11 R R (GFCI) 11.1 11.2 IDF60-20-R IDF70-20-R IDF80-20-R IDF90-20-R (A) 10 15 20 30 (mA) 30 IDF60-30-R IDF70-30-R IDF80-30 IDF90-30 (A) 10 15 20 (mA) 30
ADH-E400 1.6MPa 0.051.6MPa 0.024m 3/h 0.7MPa IDFC60/70/80/90 Series 9-1 IDX-OM-W095 L 9.3 Rc1/225 30 5 IDFC60 2722IDFC70,IDFC80,IDFC90 22 IDFC60 (IDFC70/80/90) 1) 2830Nm 2) 9.4 1 1 IDFC60/70/80/90 Series 9-2 IDX-OM-W095 R 10 R R (GFCI) 10.1 10.2 IDFC60-23-R IDFC70-23-R IDFC80-23-R IDFC90-23-R (A) 10 15 20 30 (mA) 30 IDFC60/70/80/90 Series 10-1 IDX-OM-W095 R 10.3 M3.5
CEUL/CSARoHS C3604() PBT ONBR SUS630SUS304 ( Rc1/4) SUS630SUS430 ( NPT1/4G1/4) 02Rc1/4N02NPT1/4F02G1/4(ISO1179) 3 M12 4 4 45 m 0.72 mm 1.14 mm 225 g( Rc1/4) 210 g( NPT1/4G1/4) (M12 4) () 190 g (M12 4) 3G1/4ISO1179-1 -35No.PS-OMH0002CN-D -36No.PS-OMH0002CN-D Revision history Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, 2 PORT VALVE, K40, 225 lb