T3 = V/a2 = 300/3000 = 0.1 [s] L 0.5 V (T1 + T3) V Time while the actuator is operating at a constant speed T3: Deceleration time [s] T2 = Time from the beginning of the constant speed operation to stop T4: Settling time [s] Time until positioning is completed T5: Resting time [s] Time the product is not running T6: Total time [s] Total time from T1 to T5 300 0.5 300 (0.1 + 0.1) 300
Confirm that E1 + E2 E E1 + E2 = 2.25 + 0.27 = 2.52J Since E = 3.7J, E1 + E2 E Therefore, the cylinder cushion is available for use. 21 Series CHN Technical Data 3-2 Maximum Absorbed Energy Chart & External Force and Energy Conversion Chart at Cushion Seal Contact Point Maximum absorbed energy pressure and chart in terms of cushion performance characteristics Be sure to keep the combined
(9001100) [mm] D H T E ()L d W D T Max.
Valve For VCW20 OR-1860-120Nil: NBR F: FKM E: EPDM P: PTFE OR-2380-130For VCW30 Nil: NBR F: FKM E: EPDM P: PTFE OR-2600-180For VCW40 e Nil: NBR F: FKM E: EPDM P: PTFE Manifold For VCW20 r OR-1400-178Nil: NBR F: FKM E: EPDM P: PTFE OR-2670-178When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
9200-www.stevenengineering.com E' Section E-E' CYV32 No.
5, 3 VDC E: Push-turn locking lever type Grommet L plug connector M plug connector M8 connector G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire WO: Without connector cable + + + + H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector + Note) When placing an order for body ported
Long stroke Standard stroke Without auto switch With auto switch A Long stroke (mm) Standard stroke (mm) Bore (mm) C D E OA OB Q RA RB T H I K M N With/Without auto switch A L F 7.5 7.5 9 11 B 32 32 41 44 A L 3.5 3.5 4.5 5 B 22 22 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 B 17 17 F 5 5 5.5 5.5 12 16 20 25 45.5 13.5 25.5 5 to 30 5 to 30 5 to 50 5 to 50 35 to 100 35 to 100 75 to 200 75 to 300 6 8 7 12
3 q e w t !2 !4 !3 e !0 q o Spring acting/Spring return/With auto switch (Built-in magnet) Single acting/Spring extend/With auto switch (Built-in magnet) 12, 16 !2 t w !4 y i !1 !3 e !0 q o t w !0 r q o i !1 !3 e 20, 25 w t !2 !4 !1 !3 e !0 q o w t !0 r o q !1 !3 e Component Parts Rod end nut No.
Determination of loads kinetic energy (E) bore size Determination of bore size Review of larger bore size E Es E Es E = m E 2 a ( ) 2 (Refer to page 29) 1000 P Ps P Ps Determination of pressure for intermediate stop (p) (Refer to page 29) Review of larger bore size and operating pressure Model determination 1 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F Types
speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.
1 u t q w e y !2 i r !4 !0 MX MTS MY CY !9 !8 !5 !7 MG CX MY1WK with side seal D@5 @0 @3 @4 @2 @1 -X 20Data Component Parts No. q w e r t y u i o !0 !
A C B Applicable model Dimensions [mm] A B C HECR002-A5-E 14 230 35 HECR004-A5-E 45 HECR006-A5-E HECR008-A5-E 44 HECR010-A2-E HECR008-W5-E 46 HECR012-W2-E 310 13 400 15 Option symbol F With Flow Switch F HECR Applicable model HECR002-A5-F HECR004-A5-F HECR006-A5-F HECR008-A5-F HECR010-A2-F HECR008-W5-F HECR012-W2-F With flow switch This is an ON/OFF switch detecting low levels of the circulating
100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 0 100 200 300 400 500 600 V (mm/s) LEFS 16 LEFS 25 LEFS 32 50 12 20 W(kg) W(kg) 10 W(kg) W(kg) W(kg) W(kg) 6 40 6 15 8 30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200,
YA-03 Joint YU-03 RS W M V T2 Joint Part No. 2-D through 2-O counterbore T1 B E J Applicable mounting bracket Bore size (mm) Weight (g) Joint part no.
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 13
0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
0 t t r i w e r i u w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!
300 100 MI W S 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 CEP1 Max. 500 mm/s of high speed transfer is possible.
Series NVFR40O0:Base Mounted Tlpe Constructio n/ P ar ts L i.st NVFR4 I OO 2 posi$on sirle 2 Doition double A P B E B P E 3 poBition Closed center/Erhsust center/Pressure center Closed center/NVFR43O0 I & C t 0 $ r P E E A A P B E B P E Main Parts No.
Series NVFR40O0:Base Mounted Tlpe Constructio n/ P ar ts L i.st NVFR4 I OO 2 posi$on sirle 2 Doition double A P B E B P E 3 poBition Closed center/Erhsust center/Pressure center Closed center/NVFR43O0 I & C t 0 $ r P E E A A P B E B P E Main Parts No.