SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F50-350-P"

Pilot port * Details of the mounting bolts P. 6 Stroke/Minimum stroke for auto switch mountings P. 15 Bore size Standard stroke [mm] 5 10 15 20 25 30 35 40 45 50 12 16 20 25 Applicable Auto Switches/Refer to the Web Catalog or Best Pneumatics for further information on auto switches.

P S I : 0 . 1 N d r a ' . k P a : 1 Ambient and lluid temoeralure 0 to 50'C {with no condensation) Enclosure tP65 Hated pressure I Weight tw10trn ADorox. 250 a {without options) tw20t Aoorox. 350 q (without options) tws0 Aoprox. 645 q (without options) R = ='5 Note 1) Please refer to graph 1, relation lo lhe ditferences belween lhe sel pressure and input.

F T n t kg RS H A Me 2 2 2 E 2 2 E 2 2 E 2 2 E 2 E m = 20 kg = 0.7 m/s d = 40 mm p = 0.5 MPa n = 20 cycle/min t = 25C rad/s 2.

Note 2) The seal is for 40 m and 80 m elements. 784 Vacuum Filter AFJ20 to AFJ40 Series Dimensions AFJ20 N T J M D U Bracket (Option) S SP R ZCUK C B V Q IN OUT AMJ AFJ AFJ 2 x P (Port size) AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications

NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.

1209, 1210 P. 1204 to 1206 P. 1204 to 1206 P. 1207, 1208 P. 1211, 1212 Buffer stroke Pad dia. 40 50 63 80 100 125 Buffer stroke (mm) 25 50 75 100 Pad Material and Characteristics Characteristics Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Oil resistance benzol Oil resistance gasoline Operating temperature

mm Displayable/Settable range (Distance reference) *1 0 to 60 *4 10 to 300 *4 30 to 500 *4 Minimum display unit (Distance reference) *1 1 Rated pressure range 100 to 200 kPa Displayable range (Pressure value) *2 20 to 220 kPa Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p

The theoretical output for extension is 1924N, from the theoretical output table on page 5. 20 80 50 50 50 40 60 40 40 30 40 20 10 0 0 Note: 1kg = 2.2046lb 1in = 25.4mm 1MPa = 145psi 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Operating pressure P (MPa) Operating pressure P (MPa) Selection Graphs to (Horizontal Mounting) Graph l: 100mm or less Graph l: 101 to 200mm Graph l

Speed Controller for Low Speed Operation Speed controller with One-touch fitting (resin body) Connecting tube Page Port threads AS-FM Elbow type R Metric size P.1 New New NPT Inch size Universal type R Metric size P.1 New New NPT Inch size In-line type New New Metric size Inch size P.9 Speed controller (metal body) Cylinder side Tube side AS-M R R Elbow type P.7 NPT NPT Dual speed controller

Calculation D n W P t : Pad diameter (mm) : Number of pads used : Lifting force (N) : Stable vacuum pressure (kPa) : Safety factor: Horizontal pad contact: 4 (dynamic) Vertical pad contact: 8 (dynamic) Pad W D = 3.14 x P x n x t x 1000 4 1 W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-

| '-F:# l--;:r;;P-1 ir@:-] / : I il.rdn.tnl '\ !

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -