Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: 3 pcs.
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1500mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: Spring/Air Pressure Lock, Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: 3 pcs.
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1050, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewied Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1050, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
(For accumulated increment) The following instructions must be followed during maintenance: Turn off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance work Otherwise an injury can result. [1500] 1500 L/min (PF3A703H) Reset the accumulated flow.
Rotation of the display [1500] 1500 L/min (PF3A703H) Sub display In measurement mode, the display of the sub display can be temporarily changed by pressing the or buttons. [P_1 ] Select input switch operation [3000] 3000 L/min (PF3A706H) Do not use the product for flammable fluid. Fire or explosion can result.
Accessory (Option) Tank capacity ID D With auto-drain F Companion flange Port size Capacity ( l ) 100 200 400 500 700 1000 1500 Applicable compressor (kW) 5.5 Symbol AMG 6C 04 Rc 06 14 20 30 1 2 Rc 3 4 Rc 1 1 2 2B flange 3B flange 40 4B flange AT6C AT11C AT22C/37C AT55C/75C AT125C AT150C/220C 11C 11 22C 22 AFF 37C 37 55C 55 AM 75C 75 125C 125 2000 150C 150 3000 220C 220 Misc. 14-16-1 2 Series
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
Printed in Japan 1st printing September, 2000 D-SMC.L.A. P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.
Printed in Japan. 1st printing June, 2002 D-MITAKA P-80 (DN) This catalog is printed on recycled paper with concern for the global environment.
Auto Switch Mounting Height (mm) Auto switch model D-A9 D-M9 D-M9W D-M9A D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G59F D-F5 D-J59 D-F5W D-J59W D-F59F D-F5NT Note 2) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44C D-Y69 D-Y7PV D-Y7WV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A9V D-M9V D-M9WV D-M9AV Note 2) D-P4DW D-P3DW Hs Ht Hs Ht Hs Hw Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Hs
The CLA2 cylinder acts as an air-operated brake with spring-backup. When external position feedback sends a signal to an air valve, the brake is actuated and fast-acting shoes grab the actuator shaft. When pressure is removed, the spring automatically locks the brake onto the shaft. Three locking mechanisms are available: spring lock, air pressure lock and air/spring pressure lock. The CLA2