CQU mountings include through hole/double end tapped (standard), a vertical foot bracket, horizontal foot bracket, and double clevis., Cyl, Compact, Plate type, COMPACT CYLINDER, 507, 375 lb

from three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, Multistage Ejector, VACUUM EJECTOR, M22, 375

from three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, Multistage Ejector, VACUUM EJECTOR, M22, 375

mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, E38, 375

Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, D33, 375 lb

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 375, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch