/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Magnet: Built-in Magnet, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Heavey Duty Scraper
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the
150 Standard type Symmetric type (mm) Reed switches D-A9 D-A9V Solid state switches D-F9 D-F9V 2 color indication solid state D-F9W D-F9WV MXQ 6 MXQL 6 6 MXQ 8 MXQL 8 8 MXQ12 MXQL12 12 MXQ16 MXQL16 16 MXQ20 MXQL20 20 MXQ25 MXQL25 25 Function Options Adjuster Options With Buffer Mechanism With End lock Protects work pieces and tools, etc., by eliminating impact at the end of the extension
(125: For IDF55E, 75E) D 15 4 x 13 Refrigerant R407C (HFC) IDF E C E G [mm] IDF-TBl/Dimensions Part no.
F9NV F9PV 154 154 154 Long Stroke Slide Table MXW Series 2 color indication solid state switch: D-F9BW (V), D-F9NW (V), D-F9PW (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 49.5 28.5 24.5 24.5 24.5 24.5 B 82.5 103.5 128.5 153.5 178.5 203.5 4 MXW 8 W 35.5 14.5 10.5 10.5 10.5 10.5 V 96.5 117.5 142.5 167.5 192.5 217.5 A 48 28 28 28 28 B 107
MXQ MXF MXW MXP MG MGP MGQ MGG MGC MGF CY1 MY1 3.20-13 Series MGC Auto Switch Proper Mounting Position (Stroke End) D-C7, C8 D-H7 D-B5, B6 D-G5, K5 D-B7, B8 D-G7, K7 Auto Switch Mounting Position Auto Switch Mounting Height (mm) (mm) D-G5, K5 D-G5lW D-K59W D-B5, B6 D-B59W D-G5BAL D-G59F D-B7, B8 D-B73C D-B80C D-G7, K7 D-K79C D-H7C D-G5NTL D-C7, C8 D-H7 D-H7lW D-H7lF D-H7BAL Auto switch D-B7
RESET B 8.3 P.41 RESET C OFF I/O STOP OFF OFF 8.5 ONP.44 RESET C D RESET C RESET D 66 No.JXC-OMU0004-A (M24V) RESET D RESET D 3.4 P.14 (C24V) RESET D RESET D ( E ) 67 No.JXC-OMU0004-A E ON E BK RLS E EEPROM EEPROM E 10 CPU CPU E 68 No.JXC-OMU0004-A 13. / 50mm ( ) 5m 5m 10% 15m 20% 69 No.JXC-OMU0004-A 14. / 14.1.
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
In this case, the rigidity of the machinery should also be examined. 9 - 7) How to order 25A D B 125 100 D-M9* C S2 Auto-switch Stroke Bore size Mounting bracket Built-in magnet Secondary battery production facility Air Cylinder Built-in magnet Bore size D Built-in magnet 125 125mm Nil Without magnet 140 140mm 160 160mm Mounting B L *Refer to Maximum stroke table(P5 Table 1) F G Auto-switch
R A: 0.19 A P: 0.13 VP VG Grommet (G) Body Ported Base Mounted VZ300 VP S070 M5 x 0.8 0.66 2 3 (A R) VQ L plug connector (L) VKF (Standard) VQZ 100 VAC 50/60 Hz With surge voltage suppressor (G) (L) (M) (D) With light/ surge voltage suppressor (L) (M) (D) VZ500 200 VAC 50/60 Hz 24 VDC VZ VS 2.5 2 3 (A R) (Option) N. C. N. O.
Mounting Bolt for C55 Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B63-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B32-5 -
Note 2) When symbols C or D are specified, an auto drain with a part number shown on page 18 is mounted.
P.336 P.1785 (/) (/) 19 18-2. 12 16 20 25 32 40 50 63 80 100 1 2 1 2 1 15 2 15 1 15 2 15 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 10 15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.
C D E F Dimensions Part no.
Setting Positions Mounting Height of Auto Switch (mm) (mm) D-B5 D-B6 D-B59W D-G5NTL D-H7C Hs 25.5 28 31.5 35.5 D-C7 D-C8 D-H7 D-H7W D-H7BAL D-H7F MGQ Model D-A3A D-G39A D-K39A D-A44A D-C7 D-C8 D-C73C D-C80C D-A3A D-G39A D-K39A D-A44A D-H7W D-H7BAL D-H7F D-G5NTL D-C73C D-C80C D-H7 D-H7C D-B5 D-B6 D-B59W MGG MGC A 1(0) 1(0) 2(0) 7 B 0(0) 0(0) 0.5(0) 5.5 A 6(4) 6(4) 7(5) 12 B A B 1.5(0) 1.5
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V CHQ CHQ CHK 32 to 100 20 CHN Approx. U CHM 25 CHS CH2 Approx. U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.