Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in Magnet, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Heavey Duty Scraper
Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 600mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector), Number: 2 pcs.
Auto Switch Mounting Height (mm) D-B5m D-B64 D-B59W D-G5m D-K59 D-G5NT D-G5mW D-K59W D-G5BA D-G59F Auto switch model D-F5m D-J59 D-F5mW D-J59W D-F5BA D-F59F D-F5NT D-Z7m D-Z80 D-Y59m D-Y7P D-Y7BA D-Y7mW D-M9m D-M9mW D-M9mA D-A9m D-A3mC D-G39C D-K39C D-A44C D-A3m D-G39 D-K39 D-A44 D-A5m D-A6m D-A59W D-M9mV D-M9mWV D-M9mAV D-A9mV D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW Bore size Hs Ht Hs Ht Hs
(9001100) [mm] D H T E ()L d W D T Max.
position 2.6 LC3F2 D-M9NAV/D-M9PAV D-M9BAV 500(1000)(3000)(5000) Mounting screw M2.5 x 4 L Stainless steel Indicator light Slotted set screw (flat point) Indicator light Slotted set screw M2.5 x 4 L 8 2 8 3.2 4.6 2 4.6 2.6 SMC SMC 4 2.8 2.8 2.7 22 22 2.6 2.6 2.6 9.3 9.3 4 4 6 Most sensitive position 6 Most sensitive position 507 A
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
/C8 D-H7 A B 11.5 8.5 16 Auto switch D-C7/C8, D-H7 D-B5/B6 D-G5/K5 A 12 14.5 B 24.5 Auto switch D-B5/B6, D-G5/K5 D-B7/B8 D-G7/K7 8.5 A 14.5 B 11 Auto switch D-B7/B8, D-G7/K7 Auto Switch Mounting Position D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C Auto switch model D-C7/C8 D-C73C D-C80C D-G5 D-K5 D-G5NYL D-B59W D-H7 D-H7C D-H7W D-H79F D-H7BAL Bore size (mm
V: Power supply voltage Power consumption P: 1000 [W] Q = P = 1000 [W] P Cooling capacity = Considering a safety factor of 20%, Power consumption 1000 [W] x 1.2 = 1200 [W] e Derive the heat generation amount from the output. w Derive the heat generation amount from the power supply output. Output (shaft power, etc.)
Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5
For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0
1000 0 0 0 100 0 0 0.1 2 INC 50 10.00 1000 1000 0 0 0 100 0 0 0.1 () 1No.1(IN0ON) / 2DRIVEON (2)(5)(10)(13) No.1 DRIVE (1) No.
Bolts Size Belt Belt tension Part number (N) LEF16 LE-D-6-1 9.8 pull LEF25 LE-D-6-2 19.6 LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 Bolts Size Tightening torque 6.Motor cover is installed. (Only "With motor cover") (Nm) M2.5 0.3610% M3 0.6310% M4 1.510% M5 310% The fingernail of "Grommet" is inserted in the hole of "Pulley box". Grommet 43 - 7.
Example) AL30-03B-2R Symbol Description Body size 20 30 40 50 60 10 Metric thread (M5) Rc NPT G Nil Thread type N F + M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 Port size + Nil B Note 1) Option (Mounting) Without mounting option With bracket + Polycarbonate bowl 1000 cm3 tank 1000 cm3 tank (with switch) Lowest limit ON 1000 cm3 tank (with switch) Lowest limit OFF Metal bowl Nylon bowl