SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B80TF-30DZ-A93"

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: G 32-100 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: G 32-100 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 5m, Number

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 80mm, Port Thread: G; 32 to 100 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: TF (G 32-100 Bore), Stroke: 15mm, Body Option: C (Rubber Bumper), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together), Rod End Bracket: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with p are produced upon receipt of order.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

D-A90(V) AC DC AC DC 100V or less 20mA AC DC 24V or less 50mA Maximum load current Contact protection box OUT () Brown [Red] Reed switch Reed switch Reed switch Contact protection circuit Internal voltage drop CD-P11 OUT ( ) Blue [Black] CD-P12 D-A93, A93V, D-A96, A96V (with indicator light) D-A93(V) D-A93 In-line D-A93V Perpendicular D-A96 In-line D-A96V Perpendicular Relay, PLC IC circuit

Auto Switch Internal Circuit D-A90(V) Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Auto switch model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.