SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2D50-15DM-A93"

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Action: Single Acting, Spring Return, Body Option: -, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Action: Single Acting, Spring Extend, Body Option: Rod End Male Thread, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Action: Single Acting, Spring Return, Body Option: Rod End Male Thread, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Action: Single Acting, Spring Return, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, RE, 80MM CQ2 DBL-ACT AUTO-SW, 6.35257 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, .66138 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, IE, 25MM CQ2 DBL-ACT AUTO-SW, .68588 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, FE, 12MM CQ2 DBL-ACT AUTO-SW, .36743 lb

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM