SMC Corporation of America
Elite Part Number Search
Search Results "HRS100-AN-46"

Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)

With an ejector When a few air cylinders are locally used.

The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or a return from an intermediate stop using an external stopper, etc.

In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.

An external pilot style that can be used individually is available as a made-to-order. For details, refer to the page 4-6-46.

If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.

The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98m/s2, or impact greater than 490m/s2. 3. Do not use in an area where surges are generated.

The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

(An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

(An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

(An additionally machined port will have an aluminum surface since it will be left unfinished.) Change of rotation.

In cases where the band mount type is used as an applicable auto switch, select the part number of the new band referring to page 6-8-71 whenever the cylinder model is changed.

Displacement may increase after an impact load has been applied.

In an environment where vibration or impact occurs, provide an intermediate support even if the distance is within the allowable range in the graph. W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L.

odd number, an even number that is one larger than this odd number is used for the calculation.

However, with the 25 mm adjustment bolt, an adjustment range of 0 to 26 mm is available.