113 132 20 222 250 279 25 282 319 355 32 445 494 542 639 40 517 570 623 728 50 921 1001 1081 1241 63 1256 1364 1472 1687 Use a clamp arm that is available as an option.
As a rule, turn the screw an additional 90 after tightening resistance is felt. FB 50 Stroke 66 67.5 109 109 117.5 117.5 121 141 51 Stroke or more 97.5 99 114 114 129 129 148 166 20 25 32 40 50 63 80 100 66 67.5 71.5 78 83 88 102.5 120 19 20 22 22 23 23 24 29 * Other dimensions are same as standard.
12 16 5, 10, 15, 20 25, 30 2.2-10 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 2.2-16 Solid state switch D-F9N, F9NV D-F9P, F9PV D-F9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Series CQSK 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 2.2-24 Series CQSlS 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45,
When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 2. Consider stopping accuracy and the amount of over-run when an intermediate stop is performed.
The actualor utilizes an uhra compact design by incorporartng the cylinder as patt ofthe guide bod!. As the stroke length increases, so does the beaing lcngth. This enhances the cyliniler's load capacity, Conventionally designed guided cylinders have a set bearing length resulting in dramatic decreases in sid.e load capacity as stroke kngths increase.
This seat is available as an option for high temperature applications or specific gas applications, such as N2O or CO2. [PEEK] Polyetheretherketone. This material has excellent heat, fatigue and chemical resistances as thermoplastic resin. This seat is available as an option for the regulators. [Viton] Trademark of DuPont Fluoro-rubber (FKM).
Consider selecting a ZNC series (body size 20) Bernoulli gripper as a substitute. Click here for details.
Never disassemble or modify the ionizer, as this may not only impair the products functionality but could cause an electric shock or electric leakage. 2. The tube and fitting must be treated as consumable parts.
well as the allowable eccentric load. 8-21-28 28 Series MGG Guide Cylinder With End Lock Construction 20 to 100/MGG Manual release (Lock type) !
Configurator2TM SMC part No: LEC-MRC2E) must be purchased as an additional item. *3 The USB cable (LEC-MR-J3USB) must be purchased as an additional item.
Further, the switch unit and contact protection box should be placed as close together as possible with a lead wire length no greater than 1 meter. When mounting an auto switch, insert it into the cylinder's switch mounting groove from the direction shown in the drawing below.
In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Depending on the operating environment, etc., order made products should also be reviewed. Note 3) An external guide system should be installed when over specifications. (Refer to page 6 for intermediate stops.) (Refer to pages 20 through 24.)
Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.
gravity [mm] Model LEJS40 LEJS63 LEJB40 LEJB63 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 2000 2000 1000 1000 L7 800 800 1500 1500 L7 [mm] L7 [mm] L7 [mm] L7 [mm] 600 600 1000 1000 m Me X 400 400 500 500 200 200 0 0 0 0 0 10 5 15 20 0 10 5 15 20 30 25 0 10 40 50 20 30 0
Use it when you want to remove water but air as dry as that from an air dryer is not necessary, or when a power supply for an air dryer is not available, etc.
It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed.
V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
If the operating fluid is ultra-dry air, consult SMC. 2.Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5m or smaller. 3.Therefore, take appropriate measures to ensure good air quality, such as providing an after cooler, air dryer, or water separator.
32 20 20 [Example] 25 MLU 10 10 20 ML1C 5 4 5 4 3 D3 2 2 -X 1 1 200.5 0.5 100 500 400 300 200 100 500 400 300 200 1000 1000 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 200 200 40 100 100 32 30 40 50 30 40 50 40 25 20 32 Load weight: m (kg) Load weight: m (kg) 20 20 25 20 10 10 5 4 3 5 4 3 2 2 1 1 0.5 0.5 100 500 400 300 200 100 500 400 300