SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC 1 t 1 10 x 106 100 kHz Counting speed f = = = 10 Hz 7 10 4 x 4.5 33.5 104 BCD output connector 2) UP/DOWN input Input wave form conditions: At a maximum of 100 kHz, the UP/DOWN wave form should be as shown below. 125 +12 V 10% UP pulse +12 V 10% DOWN pulse 64 59 3) 15 mA when BCD is output (Refer to page 676.) 668
Provide a specific grounding as close to the unit as possible to minimize the distance to grounding. 0 V 0 V Power supply for control/input 24 V Power supply for control/input +24 V 4. Do not install a unit in a place where it can be used as a foothold. Applying any excessive load such as stepping on the unit by mistake or placing a foot on it, will cause it to break. 5.
Keep the lead wire length as short as possible.
4.5 7 142 144 32 64 7 50 79 16 10 130 45 26 26 10 12 9.5 142 65 55 36 36 11 4.5 10 161 163 36 72 9 55 90 20 10 145 52 28 28 12 15 12 160 75 68 45 45 12 5.5 10 170 175 45 90 9 70 110 25 12 155 60 32 32 12 15 12 170 80 80 50 50 12 5.5 10 185 190 50 100 9 80 120 25 12 170 70 40 40 16 20 16 190 90 100 63 63 14 6.5 12 210 215 63 126 12 100 153 30 16 190 90 50 50 16 20 16 210 110 120 75 71 16
Since the operations above 1. to 4. are the same as Series CV3, refer to page 10-15-54.
Since the operations above 1. to 4. are the same as Series CV3, refer to page 10-15-54.
as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 73 Circulating Fluid Temperature Controller
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 100 to 240 VAC 1 t 1 10 x 106 100 kHz Counting speed f = = = 10 Hz 7 10 4-4.5 33.5 104 BCD output connector 2) UP/DOWN input Input wave form conditions: At a maximum of 100 kHz, the UP/DOWN wave form should be as shown below. 1130.2 125 +12 V 10% UP pulse +12 V 10% DOWN pulse 5 sec 64 5 sec 59 5 sec 3) 15 mA when BCD is output.
Since alignment variations increase as the stroke gets longer, use a connection method which can absorb these variations and consider measures to control particulate generation. 10-AS1301F-M5-06-X214 10-AS2301F-01-06-X214 10-AS2001F-04-X214 10-AS1001F-04-X214 In-line type (throttle valve) 10-AS2001F-06-X214 10-AS1001F-06-X214 10-ASD330F-01-06 10-ASD230F-M5-04 Dual type (speed controller)
Since alignment variations increase as the stroke gets longer, use a connection method which can absorb these variations and consider measures to control particulate generation. 10-AS1301F-M5-06-X214 10-AS2301F-01-06-X214 10-AS2001F-04-X214 10-AS1001F-04-X214 In-line type (throttle valve) 10-AS2001F-06-X214 10-AS1001F-06-X214 10-ASD330F-01-06 10-ASD230F-M5-04 Dual type (speed controller)
A DB BN BP BO DC eO eE F GA GB GC GO 10011500 50 136 Bore Size Stroke r.naecmm) (mm) WHhoot boot WHh boot GL GR J K MM 27 30 60 96 V V 44 16 32 10 as 15 26 54 40 500 20500 50 600 20-600 10 10 M8X1 .25 6 M14X1.5 32 35 70 108 V 'I, 52 20 40 10 95 17 27 59 32 35 86 11 5 V V 64 20 40 10 102 17 , 26 67 13 12 M8X1.25 7 M18X1.5 63 600 20-600 18 15 M10X1 .25 7 M18X 1.5 37 40 102 129 V V 78 25 52
Bore size (mm) 10 15 25 10 15 25 Auto switch Nil Without auto switch Refer to the table below for auto switch model numbers.
Since alignment variations increase as the stroke gets longer, use a connection method which can absorb these variations and consider measures to control particulate generation. 10-AS2301F-01-06-X214 10-AS2001F-04-X214 10-AS1001F-04-X214 In-line type (throttle valve) 10-AS2001F-06-X214 10-AS1001F-06-X214 10-ASD330F-01-06 10-ASD230F-M5-04 Dual type (speed controller) 10-ASD330F-01-08 10-ASD230F-M5
Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.
of 0.5MPa and a temperature of 20C. 7 Series AS-FG How to Order AS 200 1 F G 06 Body size Applicable tube outside diameter Metric size Inch size 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 3.2 4 6 8 10 12 23 04 06 08 10 12 With One-touch fitting Use a 1/8" tube.
Design Design Warning Warning 10. Do not use the product as a shock absorbing mechanism. If abnormal pressure or leakage occurs, there may be a drastic loss of deceleration effectiveness, with the accompanying risk of human injury as well as damage to equipment and machinery. 1.
11 17.5 1 (Bleed port) VA 1.5 A B M3 x 0.5 (Piping port) 1.5 1.5 33 36 SA Manual override B P R R (35) 7 7 36 (2) VA 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 VM 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14 14 15 (Bracket) VR VH 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 VHS 10 9 36 7.1 2-M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2-3.2 1.5 1.5 22 7 8.2
I Available as double acting or single acting.
V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 195 Thermo-chiller Basic Type HRSE Series