CP95 Auto switch mounting screw M5 x 0.8 x 16 l 1.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

wire electrical entry) P EB EA 31 50 67 81 37 37 43 6-Rc 3/4 61 103 (P , EA, EB port) 72 [ ] = A, B port Rc 3/4 Formula for manifold weight M = 0.911n + 1.621 (kg) n: Station 144 (72) 60 11 60 Non plug-in type: VV5FR5-10Station 1Bore size U side 2.3 (Electrical entry) Manual override (Non-locking) 21 R5.5 B B B B A A A A B B B n A A A B B B B A A A A 3 L2 L1 P = 51 11 11 71.5 (Pitch) P =

20 M16 x 1.5 16 M5 x 0.8 M6 x 1.0 76 60 41 32 25 16 12.5 20 M20 x 1.5 16 l M5 x 0.8 M6 x 1.0 90 70 50 40 31.5 20 16 20 M24 x 1.5 20 C B series rod M6 x 1.0 M8 x 1.25 145 115 75 60 E 40 30 20 24 M30 x 1.5 31.5 dH10 L L M6 x 1.0 M8 x 1.25 145 115 75 60 40 30 20 24 M39 x 1.5 31.5 M8 x 1.25 M10 x 1.5 185 145 95 80 50 40 25 26 M48 x 1.5 40 H+0.4 +0.1 D M5 x 0.8 M6 x 1.0 76 60 41 32 25 16 12.5

parallel motor B B-B B Component Parts Component Parts (Right/Left side parallel only) No.

D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30

AC200230V AC100120V 40 6 AC100120V AC200230V L 1 L 1 PE L 2 2-M5 2-M5 L 2 L 3 CNP1 CNP1 N N P 1 P 1 P 2 P 2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L 11 L 11 L 21 L 21 M5 3.24[Nm] U U CNP3 V CNP3 V W W 11 3 11 11.2 (1) Mini Delta Ribbon(MDR)(3M()) (a) [mm] E D A C Log 39.0 23.8 B 12.7 A B C D E 10126-3000PE 10326-52F0-008 25.8 37.2 14.0 10.0 12.0 AWG2430 (b) M2.6 [mm] E D A C F Log

L plug connector: VQD1151l-lL-M5 M plug connector: VQD1151l-lM-M5 5 5 5.5 SY 4(A) 2(B) SYJ SX VK VZ Lead wire length: 300mm Direct manual override Light 27 VF VFR SMC 17.6 11.2 3(R) VP7 9 3 2-3.5 Mounting hole 10.9 9.1 VP4 5.5 VQ VQ4 33.5 38 37 12 28.5 VQZ 1(P) 1(P) VQD 4-M5 X 0.8 5.5 (P, A, B, R port) 13 VZS L plug connector (L) 49 50.5 VFS M plug connector (M) VS VS7 1.13-7 Series VQD1000

10 6 0.01 0.1 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Graph b b Load Eccentricity 100 mm Graph , Load Eccentricity 100 mm Graph 1 Load Eccentricity 100 mm 1 10 10 Mass m (kg) Mass m (kg) Mass m (kg) 1 20 16 20 16 20 16 10 6 0.1 1 10 0.1 10 6 6 0.01 0 20 40 60 80 100 0.01 0.1 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L

Mounting bolt M5 X 75l M5 X 85l M5 X 80l M5 X 90l M5 X 90l M5 X 100l M5 X 80l M5 X 90l M6 X 105l M6 X 135l M8 X 105l M8 X 135l D 75 85 80 90 90 100 80 90 105 135 105 135 Part No.

(Refer to CAT.E501-B "Air Fittings and Tubing" for details.) Note 3) M5 and 10-32UNF type ports are not available with sealant. Note 4) All brass parts are electroless nickel plated. The knob of the M5 type and the lock nut of the meter-in type are black zinc chromated.

Stroke 16 CXSJ10P 0.3 14.4 0.3 41.4 Stroke (64.5 + Stroke) 56 + Stroke 8.5 44.5 + Stroke 7.5 8 + Stroke 16 4-M1.6 x 0.35 x 8 L 20 2-M5 x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 8-28-25 25 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L

L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-Rc 1/8 thread depth 5 SS T Bore size (mm) 2 x 2-4.3 through 2 x 2-8 counterbore with depth 4.3 2 x 2-5.5 through 2 x 2-9.5 counterbore with depth 5.3 2 x 2-6.5 through 2 x 2-11 counterbore with depth 6.3 2 x 2-6.5 through 2 x 2-11 counterbore with depth 6.3

90 Bore size (mm) 20A B A + B + 90 20 25 32, 40 50, 63 50 50 50 50 175 170 170 175 35 30 30 35 A Data Clevis Pin 2-d Dd9 d Note) Cotter pin Bore size (mm) Model l m Dd9 L (Drill through) 3 x 18 l 4 x 25 l 4 x 35 l 4 x 36 l 0.040 0.076 CD-M03 CD-M05 CD-M08 CDP-7A 10 14 22 25 20, 25 32, 40 50, 63 80 3 4 4 4 4 4.5 5 5 36 51 72 78 44 60 82 88 0.050 0.093 0.065 0.117 0.065 0.117 l m L Note) When

B L F G D *Mounting brackets are shipped together, (but not assembled).

Model C D Mounting bolt M5 x 90l M5 x 95l M5 x 100l M5 x 110l M5 x 120l M5 x 145l M5 x 170l M5 x 100l M5 x 105l M5 x 110l M5 x 120l M5 x 130l M5 x 155l M5 x 180l M6 x 120l M6 x 130l M6 x 140l M6 x 165l M6 x 190l M8 x 125l M8 x 135l M8 x 145l M8 x 170l M8 x 195l RLQB32-20 RLQB32-25 RLQB32-30 RLQB32-40 RLQB32-50 RLQB32-75 RLQB32-100 RLQB40-20 RLQB40-25 RLQB40-30 RLQB40-40 RLQB40-50 RLQB40-75

Thread size M4 x 0.7 M8 x 1.25 M5 x 0.8 M6 x 1.0 Bolt dimensions Dimension t L-7 L-8 L-8 L-12 L-9 N m 13.2 4.4 1.37 2.65 Tightening torque Square nut L t Service Life and Replacement Period of Shock Absorber Caution 1.

M L CX Plate mounting style with auto switch: CDPXW S M L Table (1) DHousing mounting style with auto switch: CDBXW M -X M L Table (2) 20Data Table (1) Plate Mounting Style with Auto Switch (CDPXW -) Component Parts for Mounting Switches and No. of Component Parts M L 10 16 20 25 32 Assembly model no. for mounting switch Component parts Material CDPXW 10SM L CDPXW 16SM L CDPXW 20SM L CDPXW

Metal bowl with level gauge Metal bowl Metal bowl Optional specifications B B B B B N.O.: Black N.C.: Gray M5 x 0.8 Barb fitting Applicable tubing: T0604 B B O S 10 One-touch fitting O S 1/4 Width across flats 17 With bracket Accessory specification Port size Standard specification With auto drain Model B 115 170 204 208 M 2.3 2.3 2.3 2.3 J 5.4 6.5 8.5 8.5 K 8.4 8 10.5 10.5 L 40 53 70 70