(M5)) (ln ca8e of % NPTF) M Vpe plug connector(M) L typ plug connector(L) 133S (340) ',3.A3 (3&) lo-32Nom. (Ms) Tgpe 40 Manifold,/ Bottom Ported(External Pilot) inch (mm) Grommet (c), (H) (ln case ol lo-3zNorn, (M5)) L type plug connector(L) 13.78 (s50) 13.,13 (s41) r3.19 (35) Symbol (internal pilot tpe) N.C. N.O. slJrb s-zrJh P R P R w (external pilot type) N.C. N.O.
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Refer to Fig. 4-1: Thrust force characteristics (P.9) and to Fig. 4-3: Allowable thrust force setting values (P.11) for details. Note 2) When mounted on a base with good heat dissipating capacity at 20oC ambient temperature. Note 3) The pushing force varies depending on the operating environment, pushing direction and table position. Refer to Fig. 4-1 Thrust force characteristics (P.9).
Use a metal P-clip (Fig.2-1), metal U-clip (Fig.2-2) when grounding.
Note 2) Unit: kPa, MPa Panel mount adapter + Front protection cover L Lead wire with connector (Lead wire length 2 m) Note) With connector cover G Connector cover D Note) For output types N and P, the number of core of lead wires will be 3, and for other types, it will be 4. 33
Although auto switches satisfy IEC standard IP67 construction expect some models (D-A3, A44, G39, K39, RNK, RPK) do not use auto switches in applications where continually exposed to water splash or splay. This may cause improper insulation or malfunction. 3. Do not use in an environment with oil or chemicals.
Although auto switches satisfy IEC standard IP67 construction expect some models (D-A3, A44, G39, K39, RNK, RPK) do not use auto switches in applications where continually exposed to water splash or splay. This may cause improper insulation or malfunction. 3. Do not use in an environment with oil or chemicals.
Flow Sensor Series PFMV5 How to Order PFMV5 05 1 Option (shipped together) Measurement flow range 0.0 to 0.5 l/min 05 10 30 05F 10F 30F None With L-type bracket Nil 0.0 to 1.0 l/min 0.0 to 3.0 l/min 0.5 to 0.5 l/min 1.0 to 1.0 l/min 3.0 to 3.0 l/min A Mounting screw Analog output (1 to 5 V) Output specification 1 2 L-type brackets (with 2 mounting screws) are included.
D-A9V/M9V/M9WV/M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation Manual: K (Operation Manual,