PROOF VALVE 3000 3000 1/32 .022 H23GG19DCV EH23GG19DCCM 3000 3000 1/32 .022 H23GG19DCV EH23GG19DCCM 2500 1500 3/64 .041 H23HH19DCVG EH23HH19DCCMG 1500 1500 3/64 .050 H23HH19DCVL EH23HH19DCCML 1750 500 1/16 .065 H23JJ19DCVG EH23JJ19DCCMG 1000 500 1/16 .070 H23JJ19DCVL EH23JJ19DCCML 650 100 3/32 .100 H23KK19DCVG EH23KK19DCCMG 300 100 3/32 .130 H23KK19DCVL EH23KK19DCCML Availability of certain
20 ML1C 700 1500 25 1000 1500 32 REA 1000 1500 40 *It is possible in each size to manufacture the cylinder with 1500 stroke maximum.
1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900
Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat. 4) Tested with Helium gas inlet pressure 1500 psig (10.5 MPa). 5) Tested with Helium gas inlet pressure 1000 psig (7 MPa). 6) On panel mount option, bonnet port is not threaded. 7) Mass, including individual boxed weight, may vary depending on connections or options.
, 900, 1000, 1200, 1500, Stroke [mm] Note1) 900, 1000 1800, 2000 1800, 2000 1 10 19 LECP6/LECP1/LECPMJ/JXC91 Work load [kg] note2) Horizontal 1 5 14 LECPA Actuator specification 48 to 1100 48 to 1400 48 to 1500 Note2)Speed [mm/s] 3,000 Max.acceleration/deceleration [mm/s2] 0.08 Positioning repeeatability [mm] 0.1 or less Lost motion[mm] note3) Equivalent lead [mm] 48 48 48 50 / 20 Impact/
It must be operated manually. 0.1 0.1 0 600 800 400 200 0 1000 0 0 500 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) AW40K-06 Rc3/4 AW40K Rc1/2 0.6 0.6 0.5 0.5 Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.3 0.3 Caution 1. Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure.
To release air that does not contain traces of lubricant, use a check valve (Series AKM) on the inlet side of the lubricator to prevent a back flow of the lubricant. 0.3 0.3 0.2 0.2 0.1 0.1 0 0 500 1000 1500 Flow rate L/min (ANR) 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) AC30 Rc 3/8 AC60 Rc 1 2.
VBA 0.3 0.3 VE 0.2 0.2 0.1 0.1 VY1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate (/min (ANR)) Flow rate (/min (ANR)) G AC30 Rc 3/8 AC60 Rc 1 PPA 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 AL 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate (/min (ANR)) Flow rate (/min (ANR)) AC40 Rc 1/2 Precautions 0.6 Outlet pressure (MPa) 0.5
VBA 0.3 0.3 VE 0.2 0.2 0.1 0.1 VY1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate (/min (ANR)) Flow rate (/min (ANR)) G AC30 Rc 3/8 AC60 Rc 1 PPA 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 AL 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate (/min (ANR)) Flow rate (/min (ANR)) AC40 Rc 1/2 Precautions 0.6 Outlet pressure (MPa) 0.5
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Body Bottom Tapped, Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1, 100 to 120V, I/O Connector: w/Connector
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Body Bottom Tapped, Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1, 100 to 120V, I/O Connector: w/Connector
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Body Bottom Tapped, Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1, 100 to 120V, I/O Connector: w/Connector
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental,
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental
Accuracy: Basic Type, Size: 25, Motor Mounting: Top Mounting Position, Motor Type: S2 [AC Servo Motor, (Incremental Encoder), Output 100W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 400mm, Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: L (Foot), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 100mm, Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input,