A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30) 23 (32) 19.5 (28.5) 40 10 13.5 35 37.5 38
A B B A B A B 18 (26) A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 6 9 3 8 10 6.5 4.5 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18 (26) 16 (24) 25 6 9 3 8 10 6.5 4.5 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 19 (27) 17 (25) 32 7 10 4 9 11 7.5 5.5 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30)
8370: JIS B 8361: JIS B 9960-1: 1 JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4
ZX B B' A B ZR A B P1 A A' ZM !0 o r t ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com e ZL ZY ZQ ZF ZP !1 ZCU Section A-A' (Ejector) AMJ !
For IITV00-n Total weight (g) Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional.
LNon-locking push style [Standard style] LLocking slotted style [B] Press in the direction of the arrow. Turn in the direction of arrow.
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size
Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.
HS SMC SMC 16 29 A B Auto switch mounting positions Minimum strokes for auto switch mounting (mm) Basic type, Foot type, Flange type, Clevis type Mounting bracket Auto switch model B D-H7BA Applicable bore size (mm) 1 pc. (Rod cover side) 2 pcs. (Different sides) 2 pcs.
4 123128PA 123129A 123182 124230 12318 123111 123126 113136 123128PA 123314A 12335A 124232 12318 123111 123313 113136 JIS B 2401G90 123128PA 123128PA 123221A 123182 124230 12318 123111 123126 113136 123128PA 123128PA 123292A 12325A 124231 12318 123111 123213 113136 JIS B 2401G80 123032 124232 12318 123111 123011 113136 JIS B 2401G90 124232 12318 123111 Urethane resin Urethane resin NBR NBR
mm 600 mm 600 mm 600 mm 600 mm 3.2.2 7 7.3 IDF-AB500 14 1 IDFC60/70/80/90 Series 3-2 IDX-OM-W095 3.2.3 60 80 80 IN OUT (IN) (OUT) IN OUT IDFC60/70/80/90 Series 3-3 IDX-OM-W095 3.2.4 12mm 5m8mm SO O S IDFC60/70/80/90 Series 3-4 IDX-OM-W095 3.2.5 7.1 0.2m IDFC60-23 IDFC70-23 IDFC80-23 IDFC90-23 16AWG (1.25mm 2) 14AWG (2.0mm 2) 911 mm 1823 mm IDFC60-23 IDFC70-23 IDFC80-23
Bushing Connecting bracket B Restrictor assembly Connecting bracket A Flow direction arrow Connecting bracket B r Mount the connecting bracket A, and tighten the hexagon socket head cap screw with the following torque.
Standard M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 10-V14: 13(27) 10-V14A: 16(30) 10-V14: 12(26) 10-V14A: 15(29) Large flow capacity Standard 10-V124A Note 1) Large flow capacity Valve model 12 [32 Note 3)] Flow characteristics 23 [21 Note 3)] b b Cv Cv C[dm3/(sbar)] 0.054 0.099 0.037 0.076 C[dm3/(sbar)] 0.037 0.076 0.054 0.099 10-V114 10-V114A 10-V124 Note 1) 0.008 0.016 0.015 0.024 0.015 0.024
Interface regulator SMC 1 P 5 3 R2 R1 PE How to Order Applicable interface regulator model Reduced pressure port Solenoid valve model ARBQ4000-00-A-1 A VQ40 (plug-in type) ARBQ4000-00-B-1 B ARBQ4000-00-P-1 P ARBQ4000-00-A-5 A VQ45 (plug lead type) ARBQ4000-00-B-5 B ARBQ4000-00-P-5 P Circuit Diagrams Reduced pressure port: A Reduced pressure port: B Reduced pressure port: P SMC Pneumatics,
B) In the state of A), attach the workpiece and the arm side block, and adjust the shim so that there is a space of about 0 mm. During this step, theoretically, there is no clamping force pressing down on the workpiece. C) In order to generate a clamping force from the state described in step B), insert an additional shim.
flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 N 9.5 11 11 18 18.5 20
A Applicable absorber B SR Dimensions RBC08C RBC10C RBC14C RBC20C RBC27C RJ08U 6.5 6.8 6 RJ10U 9 8.7 7.5 X RJ14U 12.5 12 10 16 18 20 RJ2015U 21 25 25 RJ2725U H B T 2 x D MM L Part no.
S = 5.0 600 500 400 300 200 100 VDW304 S = 8.0 900 800 700 600 500 400 300 200 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 300l/min (ANR) for orifice 2.3 (VDW20) is P1 approx. 0.77MPa, for orifice 3 (VDW30) is P1 approx. 0.45MPa, for orifice 4 (VDW30) is P1 approx. 0.24MPa.
mm) 2feet (600 mm) 2feet (600 mm) 2feet (600 mm) 2feet (600 mm) IDFB Series 2-2 2 2 IDX-OM-W020 2. 2-2-2 6 6-2 2-2-3 122F50 oC 122F 50 oC 2-2-4 IDFB Series 2-2 2 3 IDX-OM-W020 2. 2-2-5 6-1 IEC 2 3 () 812 16AWG1.251.5mm 0.1m 98feet (30m) M3 118138mil (33.5mm) PE IDFB Series 2-2 2 4 IDX-OM-W020 2. 2-3 ()2 (2 ) IDFB Series 2-3 2 5 IDX-OM-W020 3 / 3 / 3-1 INOUT 3-2 ON
Bar length (mm) IZN10-G-100-X216 IZN10-G-200-X216 IZN10-G-300-X216 IZN10-G-400-X216 IZN10-G-500-X216 IZN10-G-600-X216 100 Part no. IZN10-G-X198 Part no.