Magnet: None, Mounting: Double Clevis, Cushion: Air Cushion, Bore Size: 3/4", Stroke: 5", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Air Cushion, Bore Size: 3/4", Stroke: 1 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Cushion: Air Cushion, Bore Size: 3/4", Stroke: 1/2", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: D (Double Clevis), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0500 (5")
Magnet: None, Mounting: D (Double Clevis), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0300 (3")
Magnet: None, Mounting: D (Double Clevis), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0400 (4")
Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII
Mounting: D (Double Clevis), Cushion: A (Adjustable Cushion), Bore Size: 20 (3/4"), Stroke: 0200 (2"), Temperature Resistant: XB6 [Heat Resistant, (-10 to150°C)]
Magnet: None, Mounting: D (Double Clevis), Cushion: A (Adjustable Air Cushion), Bore Size: 20mm, Stroke: 0500 (5"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Magnet: None, Mounting: D (Double Clevis), Cushion: A (Adjustable Air Cushion), Bore Size: 20mm, Stroke: 0400 (4"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Magnet: None, Mounting: Double Clevis, Cushion: Air Cushion, Bore Size: 3/4", Stroke: 2", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Universal, Applicable Tubing: 1/8", Suffix: Required Selection w/Speed Control
Magnet: None, Mounting: Double Clevis, Cushion: Adjustable Air Cushion, Bore Size: 20mm, Stroke: 5", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Magnet: None, Mounting: Double Clevis, Cushion: Adjustable Air Cushion, Bore Size: 20mm, Stroke: 4", Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC37
Mounting: Double Clevis, Cushion: Adjustable Cushion, Bore Size: 3/4", Stroke: 2", Temperature Resistant: XB6 [Heat Resistant, (-10 to150°C)]
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.