Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 28 [NPN + Analog Output (1 to 5 V)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 29 [NPN + Analog Output (4 to 20 mA)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 29 [NPN + Analog Output (4 to 20 mA)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 68 [PNP + Analog Output (1 to 5 V)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 68 [PNP + Analog Output (1 to 5 V)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 28 [NPN + Analog Output (1 to 5 V)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 69 [PNP + Analog Output (4 to 20 mA)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit
Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: NPT, Port Size: 1", PF2A703H, Output Specification: 69 [PNP + Analog Output (4 to 20 mA)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Output Specification: PNP Open Collector 2 Outputs, Piping Specification: w/o Lead Wire, Unit: S1 Fixed Unit
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Output Specification: NPN Open Collector 2 Outputs, Piping Specification: w/o Lead Wire, Unit: S1 Fixed Unit
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Output Specification: NPN Open Collector 2 Outputs, Piping Specification: 3m Lead Wire w/Connector, Unit: S1 Fixed Unit
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Output Specification: PNP Open Collector 2 Outputs, Piping Specification: 3m Lead Wire w/Connector, Unit: S1 Fixed Unit
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Size: 4 (40), Valve Type: 2 (Normally Open), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor)
Size: 3 (30), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: E (EPDM), Port Size: 03 (Thread; 3/8), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor)
Size: 3 (Series 30), Valve Operation Type: 1 (Normally Closed), Valve Type: Nil (Standard), Body Material: S (Stainless Steel), Seal Material: F (FKM), Orifice Diameter/Port Size: 402 (Orifice Diameter: ø4mm; Port Size: 1/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor), Oil-free Option: None, Bracket: B (w/ Stainless Steel
Model Type: 56 (ATEX, Category 3), Piping: F (Direct Piping Type), Tank Size: None, Port Size: 14 [1 1/2 (40A)], Thread Type: N (NPT), OUT Port Piping: None, Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal w/Surge Voltage Suppressor, All Voltages), Fluid and Ambient Temp.: B (-40 to 60°C)
Size: 2 (Series 20), Valve Operation Type: 1 (Normally Closed), Valve Type: Nil (Standard), Body Material: S (Stainless Steel), Seal Material: F (FKM), Orifice Diameter/Port Size: 403 (Orifice Diameter: ø4mm; Port Size: 3/8), Thread Type: N (NPT), Rated Voltage: B (24 VAC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor), Oil-free Option: None, Bracket: B (w/ Stainless Steel