Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
When the I/alues 01 P1 and P2 are equal 0<" when Pi > P2 but Wlthm 2 digits. the hystereSIs Will be au1omatll~ally set 102 digits for lhe sell/alue 01 PI An error code is displayed when overcurrent, excessive pressure, data error, or pressure during O-clear occurs.
Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
Please refer to p.4.5-7 for with pressure differential gauge (GD40-2-01). 4.6-6
Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)
CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 28 28 28 30 42 42 48 56 20 25 32 40 38.3 42.1 53.8 64.6 28 28 28 30 16 20 22 30 42 42 48 56 35.8 39.8 49.4 58.4 18.1 20.7 23.6 27.3 3.2 3.2 4.5 4.5 13 15 17 21 26 28 28 36 50 57 61.4 71.4 47.8 54.8 57.4 65.4 21.2 21.3 25.6 26.3 3.2 3.2 4.5 4.5 13 15 17 21 20 25 32 40 Knuckle Pin Rod End Nut Clevis Pin
CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 28 28 28 30 42 42 48 56 20 25 32 40 38.3 42.1 53.8 64.6 28 28 28 30 16 20 22 30 42 42 48 56 35.8 39.8 49.4 58.4 18.1 20.7 23.6 27.3 3.2 3.2 4.5 4.5 13 15 17 21 26 28 28 36 50 57 61.4 71.4 47.8 54.8 57.4 65.4 21.2 21.3 25.6 26.3 3.2 3.2 4.5 4.5 13 15 17 21 20 25 32 40 Knuckle Pin Rod End Nut Clevis Pin
CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 38.3 42.1 53.8 64.6 28 28 28 30 16 20 22 30 42 42 48 56 35.8 39.8 49.4 58.4 18.1 20.7 23.6 27.3 3.2 3.2 4.5 4.5 13 15 17 21 20 25 32 40 50 57 61.4 71.4 28 28 28 30 26 28 28 36 42 42 48 56 47.8 54.8 57.4 65.4 21.2 21.3 25.6 26.3 3.2 3.2 4.5 4.5 13 15 17 21 20 25 32 40 Knuckle Pin Rod End Nut Clevis Pin
CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 13 15 17 21 3.2 3.2 4.5 4.5 21.2 21.3 25.6 26.3 47.8 54.8 57.4 65.4 42 42 48 56 26 28 28 36 28 28 28 30 50 57 61.4 71.4 CG-020-24A CG-025-24A CG-032-24A CG-040-24A 20 25 32 40 13 15 17 21 3.2 3.2 4.5 4.5 18.1 20.7 23.6 27.3 35.8 39.8 49.4 58.4 42 42 48 56 16 20 22 30 28 28 28 30 38.3 42.1 53.8 64.6 Rod End Nut Clevis Pin Knuckle Pin
Recommended tightening torque Unit: Nm Connection thread 3/4 28 to 30 1/8 7 to 9 1/4 12 to 14 3/8 22 to 24 1/2 28 to 30 1 36 to 38 Torque 1939 Conforming to OSHA Standard Pressure Relief 3 Port Valve With Locking Holes (Double Action Type) Series VHS4510/5510 Model When in the exhaust position, the valve may be padlock secured. This prevents erroneous operation.
50.5 50.5 47.5 63 63 18 28.5 15 25.5 15.5 23.5 13.5 27 17 22 12 28 59 80 80 30.5 16.5 29 15 27.5 13.5 69.5 100 100 32.5 18.5 31 17 29.5 15.5 14 Series RHC High Power Cylinder System Selection ... 2 3 1.Solenoid valve (A to G group) 2.
PAX1000, PA3000, PA5000 Proper tightening torque Nm Connection threads 12 to 14 Rc 1/4 22 to 24 Rc 3/8 28 to 30 Rc 1/2 28 to 30 Rc 3/4 PB1000 Proper tightening torque Nm Connection threads 1/6 turn after tightening by hand M5 2 to 3 Rc 1/8 Since the threaded sections of the PB1000 are resin, take particular care not to tighten any more than necessary.
28 28 30 36 46 43.4 48 59.4 71.4 86 105.4 CS1 Up to 300 Up to 300 Up to 300 CS2 Up to 300 Up to 300 Use a thin wrench when tightening the piston rod.
S Without bracket (Bottom view) Model Port size A B C D E F G H I J K L M N O P Q R S T U LFE1l3l 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 LFE1l4l 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 LFE2l 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 62 53 4.6 9.5 14 56 38 2.5 depth 8.5 2.6 LFE3l 1 120 90 55 32 73 100 106
I Shock resistance 100G to X, Y, 2 direction ( 3 times for each direction) Weight 1269 (Incl. 3m-long lead wire) Nolel)eHysleresls mode ZSE When the values 01 PI and P2 are the same or when PI >P2 wlthlll 2digits, the hysteresis will be aulomahcally 2digits for the set value of PI.
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data
Order Made 2 With IN-OUT Flange 1 With Pressure Differential Gauge (GD40-2-01) A pressure differential gauge can be installed in the body to check the life of the filter element. It allows for easier piping and compact size. For easier flange piping.
Housing Port Size (1/16 of an inch) Shaft Port Size (1/16 of an inch) Housing Port Configuration: 01 = Male NPTF(Non-Standard)* 02 = Female NPTF 03 = Male JIC 37 Degree 05 = Male SAE O-Ring Straight Thread 06 = Female JIC 37 Degree 07 = Female NPSM Pipe Swivel 10 = Female SAE Straight Thread JM = Seal-Lok Shaft Port Configuration: 01 = Male NPTF 02 = Female NPTF 03 = Male JIC 37 Degree 05
Port size Symbol Port size Model PSE570 PSE573 PSE574 PSE575 PSE576 PSE577 01 R1/8 (with M5 female thread) 02 R1/4 (with M5 female thread) For pressure switch precautions and specic product precautions, refer to the Operation Manual on the SMC website.
ZF ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 ZP Manifold ZCU AMJ Misc.