, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.
, 150, 175, 200 (mm) Bore size (mm) OB OL P PA PB PW Q RA RB RC S SA SB T U VA VB WA WB 50, 75, 100st Larger than 100st 25st 50, 75, 100st Larger than 100st 25st 117 128 168 55 74 89 54 56 71 100 125 150 24 24 35 188 225 272 70 80 100 14 14.5 17.5 Rc1/4 Rc3/8 Rc3/8 9 8 8 14 17.5 20 124 156 188 148 198 236 39 41 51 52 52 72 50 54 47 38 42 35 128 128 148 28 28 48 110 140 166 142 180 210 28
Maxlmum Permisslble 125 (8.3) 125(8.3) 125 (8.3) iledla: Alr (lubricated or oll-free), any non-flammabls, nontoxic, non-corrosive gasses except oxygen. Leakagq Port to port (intemal) not to exceed 0.030 cubic teet per minute at 100 PSIG (6.7 Kgf/cm'). Oporrllng Prossurss: 28'Vacuum to 300 PS|G (20 Kgt/cm,) Maledals: All housing pads atuminum die cas ngs.
Where the load voltage is 110 VAC. When the load voltage is increased by more than 10% to the rating of applicable auto switches above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the range of the load current range, 110 VAC.
163 225 289 6000 5 30 56 82 102 152 208 274 8000 4 26 50 76 93 137 188 245 10 3 21 45 70 89 125 172 222 12000 17 41 65 84 118 155 210 16000 9 34 57 75 110 142 188 HOW TO USE THIS TABLE 20 8 28 52 68 103 136 172 30 5 12 39 55 87 120 156 40 11 22 43 74 108 142 1 From Stroke Factors Table (see Table 1 on page 21), 50 9 15 30 66 96 130 determine the value of L. 60 14 18 57 88 119 2 In the left
to 125 kW 150A 150 kW 220A 180 to 220 kW Port size 20 2BJIS 10k flange 30 3BJIS 10k flange 40 4BJIS 10k flange 14-20-10 3 Main Line Filter Series AFF Flow Characteristics/Select the model taking the max. flow capacity into consideration.
: N Theoretical Output Weight Bore size (mm) Operating direction Operating pressure (MPa) Unit: g Without Auto Switch 0.3 0.5 0.7 Bore size (mm) Cylinder stroke (mm) IN 25 42 59 12 5 10 100 40 45 50 75 15 20 25 30 35 OUT 34 57 79 12 44 52 60 69 77 86 IN 45 75 106 16 16 56 67 77 87 97 108 OUT 60 101 141 20 183 198 213 227 92 107 122 137 152 167 IN 71 118 165 20 25 234 252 270 288 125
: N Theoretical Output Weight Bore size (mm) Operating direction Operating pressure (MPa) Unit: g Without auto switch 0.3 0.5 0.7 Bore size (mm) Cylinder stroke (mm) IN 25 42 59 12 5 10 100 40 45 50 75 15 20 25 30 35 OUT 34 57 79 12 44 52 60 69 77 86 IN 45 75 106 16 16 56 67 77 87 97 108 OUT 60 101 141 20 183 198 213 227 92 107 122 137 152 167 IN 71 118 165 20 25 234 252 270 288 125
115 297 NAC6000 1 315 285.5 48 95 78 70 110 50 12 16 10 55.2 40 117.5 311 Courtesy of Steven Engineering, Inc. !
Station n L1 L2 Station 2 77 49 Station 20 419 391 3 96 68 4 115 87 5 134 106 6 153 125 7 172 144 8 191 163 9 210 182 10 229 201 11 248 220 12 267 239 13 286 258 14 305 277 15 324 296 16 343 315 17 362 334 18 381 353 19 400 372 1-5-69
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Valve size Valve type Port size Rated voltage A: Non-locking extended type Orifice size (mm) Symbol Symbol Symbol 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Port size Rc Valve size 1 to 4 1 2 3 Note) N.C. N.O. C.O.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Valve type Port size Rated voltage Valve size 3 2 1 100 VAC 50/60 Hz Symbol Nil: Non-locking push type Orifice size (mm) Symbol Port size Rc 1 2 3 Note) 4 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Symbol N.C. 1 MPa N.C. 0.5 MPa N.O. C.O.
VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages.
VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
VX3 Rated voltage 1 2 3 4 5 6 7 8 9 Valve/Body 0 Normally cosed/Single unit 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) VXA VN Solenoid valve option Nil Standard LVC Select an option mark in page 17-3-11 by Applicable Fluids Check List for special fluids outside of the standard.
In case of 110/220VAC, VDW10 is 3W and VDW20/30 is 3.5W. Note 4) Vibration resistance No malfunction when tested with one sweep of 5 to 200Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states.
Since it can be locked at any position, it can deal with freely the changes of thickness of a workpiece. 32 50, 75 100, 125 150 40 Single knuckle joint Double knuckle joint (with pin) Dog for limit switch Dog fitting CLK1 Standard 50 Double clevis Spring rod 63 40 50, 75 100, 125 150 With magnetic field resistant auto switch CLK1G 50 63 With magnetic field resistant auto switch Series CLK1
Series CQ2 Compact Cylinder: Large Bore Size Type Double Acting, Single Rod 125, 140, 160, 180, 200. How to Order . Precautions. Specifications. Construction. Dimensions . Series CQ2W Compact Cylinder: Large Bore Size Type Double Acting, Double Rod 125, 140, 160, 180, 200 . How to Order . Precautions. Specifications. Construction. Dimensions .
Possible to install auto switches Series Variations Standard stroke (mm) Rod end configuration Applicable auto switch Action Type Bore size (mm) 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 25 Single rod 32 Reed switch D-A7 D-A8 (2-color) D-A79W Double acting 40 50 Double rod Male thread, Female thread 63 Solid state switch D-A7 D-J79 (2-color) D-F7W D-J79W 25 32 Spring return
Gas Select compatible materials of construction for the gas Operating pressure Vacuum to 125 psig (0.9 MPa) Proof pressure 200 psig (1.4 MPa) Ambient and operating temperature 14 to 160F (10 to 71C) (No freezing) Cv 0.29 0.5 Leak rate 1 x 1010 Pam3/sec Connections Compression, Rc, R, NPT Actuation pressure 60 to 110 psig (0.4 to 0.76 MPa) Actuation port connection M5 x 0.8 Actuation port