SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32TN-200-120-A93"

IR 0.5 0.5 0.6 Set pressure (MPa) Set pressure (MPa) 0.4 Set point VEX 0.5 0.3 0.4 0.0 AMR 0.3 0.2 0.2 0.5 ITV 0.1 0.1 1.0 0.0 0.0 IC 0 50 100 200 150 0 50 100 150 200 250 0.8 0.2 0.4 0.6 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Supply pressure (MPa) VBA VE Series ITV203 VY1 G Repeatability Linearity Hysteresis 1.0 0.6 1.0 PPA 0.5 Output deviation factor (%F.S.)

Next, the viscosity of 15 mPas and the discharge rate of 200 l/min in the required specification example are converted to the discharge rate for fresh water. Since 48% of the fresh water discharge rate is equivalent to 200 ml/min in the required specifications, 200 ml/min 0.48 = approximately 420 ml/min, indicating that a discharge rate of 420 ml/min is required for fresh water. 3.

5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 MGF63 Load weight m0 (kg) Load weight m0 (kg) Load

5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 Load weight m0 (kg) MGF63 Load weight m0 (kg) Load

225 237.5 L3 88 104 120 136 152 168 184 200 216 L4 17.5 15.5 14 12 16.5 15 13 17.5 16 [47.9] R 41.9 34.5 29 22.4 19.1 Manual override (non-locking) (7.5) (DIN rail dimension) Manual override In case of locking type, ( turn after pushing in. ) U side G: Approx. 300 H: Approx. 600 lead wire length ( ) D side (L4) L3 DIN rail release button 2n1-Rc(PT) 1/8 (ports A, B) DIN rail holding screw

AMD AMH Data A: Inlet Air Temperature Data B: Ambient Temperature Data C: Inlet Air Pressure AME Inlet air temperature Ambient temperature Inlet air pressure MPa psi Correction factor F C Correction factor AMF Correction factor IDFB3E to 37E IDFB55E, 75E 1.31 F C 77 90 95 100 104 25 32 35 37.8 40 75 100 110 120 125 150 175 200 232 0.53 0.70 0.76 0.83 0.86 1.03 1.21 1.38 1.60 1.24 0.95 ZFC

PP-700-5 PP-700-15 PP-700-30 PP-700-60 PP-700-100 1 1 1 3 5 5 15 30 60 100 30 60 60 120 120 0.2 0.3 0.3 0.5 0.7 0.4 0.6 1.0 2.0 3.5 PPMOUNTING STYLE BARBED FITTING (FM & PM ONLY) VALVE FUNCTION RANGE (PSI) FM = FLUSH MOUNT PM = PANEL MOUNT PT = PIPE THREAD MM = MANIFOLD B80 = NYLON 1/16" I.D. TUBE B85 = NYLON 1/8" I.D.

Single-phase 200 VAC (50 Hz) Single-phase 200/220 VAC (60 Hz) 20 Options and Available Combinations (Size/Option) A C G K L R T V Symbol Note 2) Nil With heavy duty auto drain (Applicable to medium air pressure) With terminal block for run & alarm signal Timer type solenoid valve with auto drain (Applicable to medium air pressure) With Chinese labels and a Chinese operation manual Option

l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 187.5 187.5 701 to 750 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127

As per JIS B8372 (Pneumatic regulator) VEX190 VEX110, 120 Relief Time q Relief time from 0.5MPa to 1MPa VEX130 VEX150 w Relief time from 1000 l tank VEX170 e Relief time from an arbitrary pressure [Example] VEX 1500 lowers 2000l tank from 0.4MPa to 0.1MPa: a) In graph w, b) Then, the relief time for the 2000l tank is found by conversion as shown below.

80 291 257 CG-E080SUS 23 130 32 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 CG-E080SUS 258 23 131 32 Plug bolts are installed before shipment from factory.

140 160 180 200 0 0 20 40 60 80 100 120 140 160 180 200 Temperature (C) Temperature (C) 942 LQ1/LQ3/LVN/LQHB Series Applicable Fluids Material and fluid compatibility check list for high purity fluoropolymer fittings Chemical Compatibility LVC Acetic acid 100% LVA Acetone 100% Note 1,2) LVH Ammonium fluoride 40% Ammonium hydroxide 30% LVD Butyl acetate 100% LVQ Methylne chloride 100%

VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other VY1 G Option D: Type D DIN terminal Nil G None PPA With pressure gauge AL How to Order Pilot Valve Assembly SF4 1 G 80 Y: Type Y DIN terminal Rated coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Soft start-up valve Note) The grommet

1/4W) (CN4) (CN4) (CN4) (LEC) (LEC) (LEC) 8CN1IF CONT 21 - (LEC)(LEC) 54 CN2:PC/TB (LEC)LEC-T1-3*G*LEC-W2 CN2SW(LEC)(LEC) LEC-T1-3*G*LEC-W2 1 CN2 3m 2 USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 9.CN2:TB/PC 22 - 6CN 61 1 EMG+ EMG 2 EMGEMG 3 24V + 5 4 3 2 1 4 0V 5 FG FG LEC UL , UL1310 Class2

pressure: 0.5MPa Graph to 300mm/s Graph to 500mm/s 120 80 63 63 70 100 60 Refer to graph based on horizontal mounting and load center of gravity position.

D-F5/J5 Same side 10 115 115 120 130 140 150 1 pc. 10 Different sides 10 2 pcs. D-F5W/J5W D-F5BAL Same side 10 120 120 120 135 140 150 1 pc. 10 Different sides 10 2 pcs. D-F59F D-F5NTL Same side 10 125 125 130 140 150 160 1 pc. 10 D-B5/B6 D-G5/K59 D-G5W/K59W D-G59F D-G5BAL/G5NTL Different sides 15 2 pcs. Same side 75 110 110 115 125 135 145 1 pc. 10 Different sides 20 2 pcs.

Mounting bolt C D Mounting bolt Mounting bolt Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63

CN3 5.3 CN1CONT (LEC-CG-)(LEC) DC24V CN1 (120 1/4W) CN4 CN4 CN4 (LEC) (LEC) (LEC) 8. CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQC2000 800 700 600 500 400 300 200 100 0 VQC4000 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.

External gripping force Internal gripping force MHS2-32D MHS2-32D 150 150 Pressure 0.6MPa Pressure 0.6MPa 120 120 0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 90 90 0.3MPa 0.3MPa 60 60 0.2MPa 0.2MPa F 30 30 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 F Gripping point L mm Gripping point L mm MHS2-40D MHS2-40D 250 250 Pressure 0.6MPa Pressure 0.6MPa 200 200 External gripping