Frequency (Hz) 45 40 55 50 65 60 Inrush Frequency (Hz) 50 45 55 50 65 60 50 60 50 60 50 60 50 60 50 60 50 60 9 7 19 16 30 25 11 8 20 18 32 27 VX21 VX21 VX22 VX22 VX23 VX23 Note) The values are for an ambient temperature of 20C and at the rated voltage.
0.1 0.1 5 L L 0 20 30 50 60 Holding point L (mm) 40 70 0 30 40 60 70 Holding point L (mm) 50 80 90 2.8-4 180 Angular Gripper Series MHY2/MHW2 MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7MPa Pressure 0.7MPa Pressure 0.7MPa 250 20 0.6 80 0.6 0.6 Holding force (N) Holding force (N) Holding force (N) 200 0.5 0.5 0.5 60 15 0.4 0.3 150 0.4 0.4 40 10 0.3 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40
14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 258 CG-E080SUS Plug bolts are installed before shipment from factory.
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.
100 100 100 Vacuum pressure [kPa] 80 90 90 60 80 80 40 Suction flow (High-noise reduction silencer exhaust) Vacuum pressure 70 70 Port exhaust 20 Silencer exhaust/Complex exhaust Vacuum pressure [kPa] 0 0 10 20 30 40 50 60 Suction flow (Port exhaust) 60 60 Suction flow [L/min (ANR)] 50 50 Flow Rate Characteristics Suction flow (Silencer exhaust/ Complex exhaust) Suction flow (Silencer exhaust
2 L MRHQ 0 10 20 30 40 50 60 0 50 100 150 Misc.
CJ216 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 16 Air cushion is not available for 21-/22-.
C 5 to 45 Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity 50/60 Hz3 kW 8.0/9.0 Heating capacity 50/60 Hz4 kW 1.7/2.2 Temperature stability5 C 0.5 Circulating fluid system Rated flow 50/60 Hz (Outlet)6 L/min 29/45 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50
132225 K 12 48 36 6.5 12 43.5 0.5 6.5 46 Z ZZ H G (NN 1) x H 26 10.5 26 10.5 A B 9.5 5.1 5.1 11 11 29 1.5 A B NN x M6 x 1 thread depth 12 6 5H9 ( ) depth 5 +0.030 0 GA HA B-B A-A 5H9 ( ) depth 5 +0.030 0 (mm) Model F 45 40 48 58 42 55 50 55 62 N 4 4 4 4 6 6 8 8 8 G 22 22 22 22 17 18 37 56 H 46 46 46 56 56 56 59 62 NN 2 2 2 2 3 3 4 4 4 GA 18 18 18 22 48 73 74 96 118 HA 50 50 50 56 48 56
M2 m1 M3 30 50 200 m3 Allowable moment (Nm) Allowable moment (Nm) MY1C Load weight (kg) 40 Load weight (kg) Diagonal cam follower 20 45 Lateral cam follower 50 30 100 20 10 10 0 MY2C 0 0 16 25 40 0 16 25 40 16 25 40 16 25 40 Bore size (mm) Bore size (mm) Bore size (mm) Bore size (mm) Diagonal cam follower 60 Lateral cam follower MY2HT MY2H MY1H MY2HT MY2H MY1H MY2C MY1C MY2C MY1C Features
Specification 2.1 Slider type LEF Series / Ball screw drive Specification (1) Step motor (servo 24VDC) Ball screw drive LEFS16 LEFS25 LEFS32 Model 50 to 500 50 to 800 50 to 1000 Stroke [mm] Note1) 14 15 12 25 30 20 45 50 LECP6/LECP1/LECPMJ/JXC91 Work load [kg] Note2) Horizontal 9 10 10 20 20 15 40 45 LECPA 2 4 0.5 7.5 15 4 10 20 Vertical 500 10 to 700 5 to 360 20 to 1100 12 to 750 6 to 400
(D) H H J I I G Note 1) G Note 1) J J I G Note 1) Y Y C Y C C E (A) E E (A) (A) B B 45 45 45 B X X X X C C C SMC G Note 1) G Note 1) I G Note 1) I J J F H F J (D) I (D) RG RT RS B 720 819 C 300 303 D 376 449 E R310 R445 F 60 87 G 93 129 B 780 851 C 301 300 D 369 418 E R390 R495 F 60 87 G 93 129 B 730 790 C 302 304 D 424 508 E R350 R440 G 93 129 H 302 327 A 791 916 A 823 906 A 835 934 15
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications Model HRSH090-Al-20-l HRSH090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) (GWP1975) Refrigerant charge kg 1.32 Control method PID control Ambient temperature/humidity Note 1), 9) C/% 5 to 45/30 to 70% Circulating fluid Note 2) Tap water, 15%
Mitsubishi Electric Corporation Yaskawa Electric Corporation Nil Bottom Motor output G R Y Stroke 50W 1 2 3 100W 200W Lead screw lead 20mm C Power supply voltage Slide screw S Lead screw type 100/110VAC 50/60Hz 100/115VAC 50/60Hz 200/220VAC 50/60Hz 200/230VAC 50/60Hz 1 The tables above show the definition for each symbol only and cannot be used for actual model selection. 2 Without motor
(Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF.
Max. load current or current range (mA) None 5 to 50 5 to 50 5 to 25 5 to 12.5 20 50 25 12.5 30 D-A53 PLC 24VDC 24VDC 100VAC 200VAC 4 to 8VDC 24VAC/DC or less 100VAC 200VAC Max. 24VDC D-A54 Relay, PLC None IC circuit D-A56 None D-A64 Relay, PLC D-A67 None None (2 color indication) IC circuit, PLC D-A59W 5 to 40 24VDC Relay, PLC 5 to 50 5 to 50 5 to 25 5 to 12.5 50 40 20 5 to 40 5
or less 47 or less Metal seal VQC4300 Closed center VQC4000 7.0 6.4 0.34 1.9 0.42 1.9 50 or less 52 or less 3-position pressure center Rubber seal VQC4301 (A) 4 (B) 2 6.2 6.9 0.18 1.5 0.17 1.7 45 or less 47 or less Metal seal VQC4400 Exhaust center 280 7.0 7.3 0.38 1.9 0.38 2.0 50 or less 52 or less Rubber seal VQC4401 6.2 6.4 0.18 1.9 0.18 1.6 45 or less 47 or less Metal seal VQC4500 Pressure
50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.
Refer to the cylinder catalog for details. 10 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: 8 Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 32 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 40 50 63 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke