(Including insulating material) 1.27 mm 2.35 mm Connection type Screw tightening Rated current 4 A 8 A 9 A Rated voltage 60 V 600 V 250 V Contact resistance 5 mW or less Insulation resistance 100 MW or more Withstand voltage 1.0 kV 1.4 kV 4 kV Rating/Performance temperature Connector 25 to +90C 25 to +80C 25 to +85C Cable 25 to +80C 10 to +105C Ambient Min. bending radius (Fixed) 59 mm
Additional weight 0.23/50 stroke Stroke 100 stroke 0.46 + 100 / 50 X 0.23 = 0.92kg Standard Stroke (mm) Size Standard stroke Max. stroke(mm) 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Contact SMC for any intermediate strokes that are not indicated above, as they will be produced upon receipt of order.
1 EJECTOR MULTISTAGE Multistage Ejector Series ZL112/212 Energy-saving, large flow rate, 3 stage diffuser construction ZX Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage perf stage perfor ormance mance 1 stage performance Vacuum pressure ZR Q1 Q2 Q3 ZM Q1 Q2 Q3 Maximum suction flow rate (l/min (ANR))
Note 2) 1 Body VHS20PW-180AS VHS30PW-180AS VHS40PW-180AS VHS20PW-190AS VHS30PW-190AS VHS40PW-190AS White VHS20 VHS30 VHS40 VHS40-06 VHS50 ADC12 Flame resistant PBT 2 Bonnet ADC12 White (UL-94 Standard V-0 equivalent) VHS40PW-180-06AS VHS50PW-180AS VHS40PW-190-06AS VHS50PW-190AS Flame resistant PBT 3 Handle ADC12 Red (UL-94 Standard V-0 equivalent) 4 5 6 7 8 Cam ring Spool Spool O-ring Spool
200 V 800/40 1600/80 1600/80 2400/130 3200/180 * The inrush current of the heater flows for several tens of seconds when using 100 V, while it flows for several seconds when using 200 V.
Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] 140 120 160 120 100 140 100 120 80 100 80 60 80 60 60 40 40 40 20 20 20 0 0 0 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] ZNC60m ZNC80m 300 200 180 Air consumption [L/min (ANR)] Air consumption [L/min
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.5 1 Point of application L Workpiece weight m kg 0.1 Transfer speed V m/min 30 20 10 5 5 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 30 20 100 L = 120 mm L = 100 mm L = 80 mm L = 60 mm L = 40 mm 40 L = 240 mm L = 200 mm L = 160 mm L = 120 mm L = 80 mm L = 180
-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 23 M8 x 1.25 Thread depth 8 35 6 84 180 2.4 3.4 28 35 M8 x 1.25 Thread depth 8 50 8 91 240 3.6 5.0 44 50 M8 x 1.25 Thread depth 9 62 10 103 300 5.4 7.8 62 77 M10 x 1.5 Thread depth 12 10 118 360 9.7 13.5 90 102 M10 x 1.5 Thread depth 12 5 133 340 10.6 14.4 115 Note) Both flange and thread connections are supported.
160, 180, 200, 250 0.7 AS800-12 1 4 35,400 1 540 38,500 586 1.4 AS900-14 1 2 52,000 1 792 47,500 724 300 3.3 AS900-20 57,800 2 880 60,800 926 3.3 Note) Flow rate values are measured at 0.5 MPa and 20C.
pressure rise alarm / / / / Ambient temperature *3 212 TEMP READY Band width Lower Limit 050 EASY mode ON -10 100 Unused*3 HIPRS WAKE EASY MODE AMB TEMP READY LBAND AMB LOTEMP Detection time of circulating fluid discharge pressure rise alarm Pressure of higher pressu rerefrigerant circuit 000 / / / / / TEMP READY stabilization time 5 resetKey click sound ARN ON Switch leakage alarm 5 180
screen No.10 screen Unused OFF EXTCtrl No.11 screen Unused 0.0 EXTOFSET No.12 screen Unused 35.0 EXTHI.TMPLIMIT No.13 screen Unused 10.0 EXTLO.TMPLIMIT 5.5.3 No.14 screen Unused 10 EXTTIME SEC No.15 screen TEMP READY bandwidth upper limit 1.0 0.1 to 9.9 READYH.BAND No.16 screen TEMP READY bandwidth lower limit -1.0 -9.9 to -0.1 READYL.BAND No.17 screen TEMP READY stability time 180
Time for monitoring the communication error 180 sec When the customer's device is sending messages every 60sec, if the communication cable is disconnected and no message is received for 180sec, the product generates AL19 communication error alarm to notify the error. This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec.
Time for monitoring the communication error 180 sec When the customer's device is sending messages every 60sec, if the communication cable is disconnected and no message is received for 180sec, the product generates AL19 communication error alarm to notify the error. This product Your system Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec. Passage of 180 sec.
181 (1) 178 bit1 Bit0 0 0 0 1 1 0 (2) 0(OFF)1(ON)1(ON)CN2SWON (3) 0(OFF)1(ON)1(ON)CN2SWON (4) 0(OFF)1(ON)(LEC)1(ON)0(OFF) (5)() IDON(1)IDOFF(0) bit 7 6 5 4 3 2 1 0 179 ID8 ID7 ID6 ID5 ID4 ID3 ID2 ID1 180 ID1ID8 (6) (LEC)IDID2 11201212 bit 3 2 1 0 ID 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 12 1 1 0 0 40 - 13.
Manifold Fitting Nomenclature 1/8 M = 1/8 Male NPT one end & branch outlets as required 1/8MM = 1/8 Male NPT and mixed branches 1/8MV = 1/8 Male NPT and 2nd row at 60 either L or R 1/8MMV = 1/8 Male NPT w/mixed branches at 60 either L or R 1/8MT = 1/8 Male NPT with branches at 180 1/8MMT = 1/8 Male NPT w/mixed branches at 180 1/8MB = 1/8 Male NPT Manifold blank (wall thickness suitable for
= 80 mm L = 60 mm L = 40 mm 10 Workpiece weight (kg) Workpiece weight (kg) 5 1.0 0.5 1 Point of application L Workpiece weight m kg 0.1 Transfer speed V m/min 30 20 10 5 5 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) MIW20 MIS20 MIW25 MIS25 MIW32 MIS32 30 20 100 L = 120 mm L = 100 mm L = 80 mm L = 60 mm L = 40 mm 40 L = 240 mm L = 200 mm L = 160 mm L = 120 mm L = 80 mm L = 180
When using this type, refer to Auto Switch Hysteresis on page 26 1 Parallel Type/Standard Type Series MHZ2 Specifications Fluid Air 10: 0.2 to 0.7 MPa 16 to 25: 0.1 to 0.7MPa Double acting Operating pressure 10: 0.35 to 0.7MPa 16 to 25: 0.25 to 0.7MPa Normally open Single acting Normally closed Ambient and fluid temperature 10 to 60 Repeatability 0.01mm Maximum operating frequency 180 c.p.m
In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type
Stroke Table Long strokes (mm) Max. manufacturable stroke (mm) Bore size (mm) Standard strokes (mm) Note 1) Lock Unlock 20 25, 50, 75, 100, 125, 150, 200 201 to 350 25 301 to 400 32 301 to 450 25, 50, 75, 100, 125, 150, 200, 250, 300 40 1500 301 to 800 50, 63 301 to 1200 80 301 to 1400 Locked condition Unlocked condition 100 301 to 1500 Note 1) Intermediate strokes other than the above are
Non-lube type 125, 140, 160 Spring locking Double acting Cylinder Specifications Type Non-lube type Fluid Air Proof pressure 1.57MPa {16kgf/cm} Maximum operating pressure 0.97MPa {9.9kgf/cm} 0.08MPa {0.82kgf/cm} Minimum operating pressure 50 to 500mm/s Piston speed Ambient and fluid temperature Without auto switch: 0C to 70C With auto switch: 0C to 60C (with no freezing) Cushion Yes to 250