SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32TN-175-50"

28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.

45 L 15 50 CQ-M3 x 50 L 20 55 CQ-M3 x 55 L 25 60 CQ-M3 x 60 L 30 65 CQ-M3 x 65 L 35 70 CQ-M3 x 70 L 40 75 CQ-M3 x 75 L 45 80 CQ-M3 x 80 L 50 85 CQ-M3 x 85 L 20 5.5 D C 5 45 CQ-M3 x 45 L 10 50 CQ-M3 x 50 L 15 55 CQ-M3 x 55 L 20 60 CQ-M3 x 60 L 25 65 CQ-M3 x 65 L 30 70 CQ-M3 x 70 L 35 75 CQ-M3 x 75 L 40 80 CQ-M3 x 80 L 45 85 CQ-M3 x 85 L 50 90 CQ-M3 x 90 L 25 8 6 MXZ Series Dimensions: MXZ12

CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages, please consult with SMC.

) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 500 20 115 37 400 267.4 230 510 915 1250 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 750 20 130 50 400 267.4 230 510 1175 1510 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 1000 20 150 64 400 267.4 230 510 1440 1775 100 150 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 40 (1 1/2B) 25 (1B) 620 9 500 20 150 54 445 318.5 240 560 935

0.5MPa 0.5MPa 60 60 Holding force (N) Holding force (N) 50 50 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 30 30 0.2MPa 0.2MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Holding point L (mm) Holding point L (mm) 2.3-6 Series MHR2/MDHR2 Construction MHR2 !

B to Nominal filtration accuracy of 5, 10, 25, 50, 100 m can be selected.

MHR2-10/MDHR2-10 MHR2-20/MDHR2-20 50 60 Overhang distance H (mm) Overhang distance H (mm) 50 40 Pressure 0.2 MPa Pressure 0.2 MPa 40 30 30 0.3 MPa External grip 0.3 MPa 0.4 MPa 20 0.4 MPa 20 0.5 MPa 0.5 MPa 0.6 MPa 10 0.6 MPa 10 0 10 20 30 40 50 0 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-

Storage Service life cycles/Discharge per cycle (reference) Series Diaphragm material Discharge per cycle PTFE NBR Approx. 40ml PA3000 automatically operated type 100 million cycles 50 million cycles Approx. 100ml PA5000 automatically operated type 50 million cycles 50 million cycles Approx. 22ml PA3000 air operated type 50 million cycles In case of long term storage after use with water

0.34 40 0.28 30 0.21 20 0.14 0 10 0.00 0.07 0 50 100 150 200 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.

Action D Double acting Cylinder stroke Bore size (mm) Standard stroke (mm) Mounting Bore size 10, 20, 30, 40 10 Through hole & double end tapped (standard) Foot type Front flange type Rear flange type Double clevis type B L F G D Note) 10 16 20 25 28 10mm 16mm 20mm 25mm 28mm 10, 20, 30, 40, 50, 60 16 10, 20, 30, 40, 50, 60 20 10, 20, 30, 40, 50, 75, 100 25 10, 20, 30, 40, 50, 75, 100 28 Note

/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages

to 600 Accumulated pulse output wiring examples NPN 2 output type LFElAlll NPN + Analog output type LFElClll/LFElDlll Max. 28 V, 80 mA Black OUT1 Load White OUT2 (LFE A only) Load 0 V or Blue DC () 50 ms 50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator light is turned off

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact P/A regarding other voltages.

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 210VAC (50/60Hz) 24VDC 12VDC Port size Contact SMC regarding other voltages.

-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40 (1 1/2B) 40 (1 1/2B) 1 1/2 1 1/2 160 160 50 (2B) 50 (2B) 260 260 65 (2 1/2B) 450 80 (3B) 600 Note) Tapered female thread connection conforming to JIS B

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.

Linear Motion/Standard Motion Size Standard stroke (mm) 32/40 5, 10, 15, 20, 25, 30, 40, 50, 75, 100 Refer to p.1.5-18 for other intermediate strokes.

DGraph (2) Cylinder Output on the Retracting Side (Double acting) 20150 1500 Tube bore size [mm] 100 1000 40 Side load Balance weight 40 50 400 500 32 20 25 30 200 250 300 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 15 150 Allowable Side Load on the Piston End (Nm) 10 100 Stroke of linear part Size 40 5 10 15 20 25 30 40 50 75 100 4 5 40 50 32 40 14 14 13 13 13 12 12 11

Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting

5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature C