SMC Corporation of America
Elite Part Number Search
Search Results "VQD1000-V-04-5"

Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.C

Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.O

size Rc1/ 2 Manifold Options Individual SUP spacer VVQ5000-P-5Blank plate assembly VVQ5000-10A-5 Individual EXH spacer VVQ5000-R-5EXH blocking plate VVQ5000-16A-2 03 04 03 04 Throttle valve spacer VVQ5000-20A-5 SUP stop valve spacer VVQ5000-37A-5 SUP blocking plate VVQ5000-16A-1 Double check spacer with residual pressure release valve VVQ5000-25A-5 PUSH LOCK Direct exhaust with silencer

4 P. 17-5-117 Elbow LQ2L 5 VXA 2 VN 3 Female LVC 4 P. 17-5-118 5 LVA 2 LVH 3 Male LVD 4 P. 17-5-119 Run tee LQ2R 5 LVQ 2 LQ 3 Female LVN 4 P. 17-5-120 5 TI/ TIL 2 PA 3 Male PAX 4 P. 17-5-121 Branch tee LQ2B 5 PB 2 3 Female 4 P. 17-5-122 5 2 3 Union elbow LQ2E 4 P. 17-5-123 5 2 3 Union tee LQ2T 4 P. 17-5-123 5 Note) Basic size With reducer 17-5-95 24 Series LQ 1 2, LVN, TL/TIL Port size Tubing

BK 9 9 2 V G 3 U U [ ] 1 RD 18AWG BK 5 5 1 U (CN3) PM PUMP 7 7 Option T1 6 6 4 4 3 3 2 2 1 1 PM PUMP 2/2 PM PUMP (CN1) 16AWG G/Y G4 [ ] V G PM 16AWG G/Y G4 [ ] G U DC Power Supply Standard BL DCPS [ ] 18AWG G/Y G2 5 5 Condenser 18AWG BK 1 1 3 3 3 3 18AWG BK 3 3 1 1 1 1 C3 (CN51) (CN1) (CN6) Compressor CM CM AC Power Board 3 1 PCB1 3 3 [ ] TH 14AWG BK 14AWG BK C CM 2 Current Transformer S

Series VQ5000 Base mounted Base Mounted Plug-in/Plug Lead: Single Unit Model Response time (ms) Flow Characteristics Series Number of solenoids Weight (kg) Model Port size 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Standard 1 W AC Low wattage 0.5 W b Cv b C[dm3/(s.bar)] C[dm3/(s.bar)] Cv 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 Single VQ51 0 12 35 or less 0.59 (0.67) 0.14 38 or less 2.9

Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the

Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the

F9BWV 2-wire Relay, PLC IC circuit No 5 V, 12 V 100 V or less 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Solid state switches marked with are produced upon

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 8 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 9 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 1 Station, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 2 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 3 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 10 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 6 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 5 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 7 Stations, Voltage: 5 (24 VDC)

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 9 Stations, Voltage: 24 VDC, Electrical Entry: -, Blanking Plate: -, CE-compliant: -

Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 1 Station, Voltage: 24 VDC, Electrical Entry: -, Blanking Plate: -, CE-compliant: -