Reference dimensions of 10-32UNF and NPT threads after installation. 15-9-47 6 Series AS-FG Dimensions: Universal Type Applicable tubing O.D. d (Hexagon width across flats) Applicable tubing O.D. d M5 type U10/32 type (Hexagon width across flats) Metric Size Inch Size Model d T Weight (g) H D1 D2 L1 L2 L3 L5 A Model d T Weight (g) H D1 D2 L1 L2 L3 L5 A D3 L4 Max. Min. Max. Min.
Supply port 2-M5 x 0.8 FC FA FE FH GD GC GB FG FF EB EA D FB B MIS12-10 A C FD GA Model 72 92 112 86.5 106.5 126.5 33 43 53 38.5 48.5 58.5 48 38 28 165 135 105 18 185 155 125 MIS12-30 MIS12-20 19 9.5 6 (Effective depth 3) 4.5 8 -0.1 0 8 -0.1 0 10 M3 x 0.5 5 3.3 23 26 21 MIS20-30 MIS20-20 MIS20-10 52 42 32 11-0.1 0 11-0.1 0 29.5 35 25.5 13 12.5 10 (Effective depth 4) M5 x 0.8 6.5 28.5 7 5.1
Supply port 2-M5 x 0.8 FC FA FE FH GD GC GB FG FF EB EA D FB B MIS12-10 A C FD GA Model 72 92 112 86.5 106.5 126.5 33 43 53 38.5 48.5 58.5 48 38 28 165 135 105 185 155 125 MIS12-30 MIS12-20 18 19 9.5 6 (Effective depth 3) 4.5 8 -0.1 0 8 -0.1 0 10 M3 x 0.5 5 3.3 23 26 21 MIS20-30 MIS20-20 MIS20-10 52 42 32 11-0.1 0 11-0.1 0 29.5 35 25.5 13 12.5 10 (Effective depth 4) M5 x 0.8 6.5 28.5 7 5.1
Seal Type: Metal, Configuration: 3-Position, Exhaust Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 2-position, Dual Pressure, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Exhaust Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Closed Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Posiiton, Closed Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Pressure Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Pressure Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Posiiton, Closed Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Exhaust Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Pressure Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Closed Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Dual Exhaust Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 2-position, Dual Pressure, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 3-Position, Pressure Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
AS-FG AS301FS, AS311FS AS401FS, AS411FS AS-FP Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa AS-FM 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 AS-D 06, 07 1000 AS-T 500 ASP 500 ASN 0 0 5 0 10 5 0 10 AQ Number of needle rotations Number of needle rotations ASV Note) The numbers above the flow rate characteristic curves
2 to 20 stations D side: 2 to 10 stations U side: 2 to 10 stations M Mixed Nil Standard length (Specify a longer rail than the standard length.)
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/4, Option: -