Vs: Power supply 24VDC 12 to 15VDC One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2. S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa.

Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.

Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.

(the condition of P1 and Q1) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to 0 (atmospheric pressure). When adsorbing work pieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high.

(condition P1 and Q1) 3. When suction port is opened further, suction flow moves to maximum value (Qmax), but vacuum pressure is near 0 (atmospheric pressure). When vacuum port (vacuum piping) has no leakage, vacuum pressure becomes maximum, and vacuum pressure decreases as leakage increases. When leakage value is the same as max. suction flow, vacuum pressure is near 0.

Pmax P1 Vacuum pressure Qmax Q1 Suction flow rate 13-6-4

Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries.  Due to the compact design of the ZA, it is possible to install on moving parts.  The shortened tube length to pad improves response time.  The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters.  Compact

Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries.  Due to the compact design of the ZA, it is possible to install on moving parts.  The shortened tube length to pad improves response time.  The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters.  Compact

Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries.  Due to the compact design of the ZA, it is possible to install on moving parts.  The shortened tube length to pad impro, COMPACT VACUUM GENERATOR, VACUUM EJECTOR, L93, 50 lb

Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries.  Due to the compact design of the ZA, it is possible to install on moving parts.  The shortened tube length to pad improves response time.  The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters.  Compact

Designed for high speed break response handling applications, SMC's ZQ series can be used as a stand alone ejector, or as part of a vacuum pump system. The ZQ not only offers a light weight, compact design (10mm body width), but also includes options such as filtration, pressure switches, and vacuum break (blow off valve).Compact vacuum pump unit, Body width: 10mm , Light weight: 109g (single

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ZA NOZZLE SIZE 0.5, VACUUM SERIES, ZA COMPACT VACUUM EJECTOR, AG, ZA NOZZLE SIZE 0.5, 0.22046 lb

The ZX is a single-stage vacuum generator. The modular design allows the user to choose only the components needed for the application. The ZX is available with a combination of generator unit, supply/release valve unit, pressure switch unit, and suction filter unit. Order without the generator unit for use as a filter and valve assembly for house vacuum systems. Special function plates

Main Body Shape: Unit, Additional Function: Silencers / Valves for Vacuum Generation / Vacuum Destruction Support, Ultimate Vacuum(kPa): -84, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Individual Item, Operating Temperature Range(°C): 5:50~, Suction Flow(l/min): 22, Nozzle Diameter: 1.0mm, Exhaust specifications

Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destruction Support / Central Exhaust Specification, Ultimate Vacuum(kPa): -84, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Operating Temperature Range(°C): 5:50~, Suction Flow(l/min): 22, Nozzle Diameter: 1.0mm, Exhaust

Nozzle Diameter: ø1.3, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Nil, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: -, Manual Override: -, Switch: -, Lead Wire: -, Mounting Style: -

Nozzle Diameter: ø0.7, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Nil, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: -, Manual Override: -, Switch: -, Lead Wire: -, Mounting Style: -