AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-R005 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
M1 M2 Weight (g) ASV310F-01-06S ASV310F-01-08S ASV310F-02-06S ASV310F-02-08S ASV410F-01-08S ASV410F-01-10S ASV410F-02-08S ASV410F-02-10S ASV410F-03-08S ASV410F-03-10S ASV510F-02-10S ASV510F-02-12S ASV510F-03-10S ASV510F-03-12S ASV510F-04-10S ASV510F-04-12S 71.9 73.8 71.9 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.8 90.2 91.8 90.2 91.8 16.8 19.3 16.8 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3
-01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions, make determinations after using the P/A
Model Port size 4 6 8 10 12 ASD One-touch fittings for AS121-M5 AS221-01 AS221-02 AS321-02 AS321-03 AS421-04 M5 x 0.8 AS 1 8 R metal body specifications 1 4 R AS-FE 1 4 Uses flame resistant resin as standard. (UL standard V-0) R 3 8 R KE 1 2 R Note 1) : Brass parts are electroless nickel plated, provided as standard.
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8 2 Speed Controller with One-touch Fitting Elbow Type (Metal Body) Series AS Flow Rate and Effective Area AS321-03 AS421-04 AS221-01 AS221-02 AS121-M5 Model Tubing O.D. 12 10 10 8 6 8 4, 6 6, 8 Controlled
CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
or left side is available. 865 A Air Catch Sensor Series ISA2 How to Order Manifold IISA2 N 3 B PL Without control unit SL C 3 B 1 E2 D With control unit IISA2 Pressure gauge of regulator Note 1) A Without pressure gauge Note 2) Square embedded pressure gauge E2 Z2 MPa single notation psi single notation MPa single notation psi single notation MPa single notation 0.2 MPa Control unit C V
-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (4) 1 Plug-in Unit (3) Direct exhaust with silencer box: Exhaust from both D and U sides Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust IP65 enclosure (except F and T1 kits) (2) 1 station Station (2) 01
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)