Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire. Do not convert the wiring to use. In European countries, a circuit breaker that meets the IEC standard should be used for the supply power. There are two methods depends on model (specified power).

Description Note 1A Rod cover 1B Seal retainer 6 only 2 Head cover A 3 Cylinder tube 4 Piston rod 5 Piston A 6 Piston B 7 Bumper A 8 Bumper B 9 Rod seal 10 Piston seal 11 Tube gasket 12 Wear ring 13 Mounting nut 14 Rod end nut 15 Magnet 23 - Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications

Displacement Use in a strong light source. Check that the Card Motor is not exposed to a strong light source such as direct sunlight. Install a light shielding plate as a cover.

Standard wiring of the manifold is for a double-solenoid valve. The output number starts at the A side and then B side in that order as shown in figure a. If a single-solenoid valve is mounted on the standard wiring manifold, the output number for the B side solenoid valve is skipped.

Insert panel mount adapter B into section A of panel mount adapter A. Push panel mount adapter B from behind until the display is fixed onto the panel. The pin of panel mount adapter B engages the notched part of panel adapter section A to fix the display. The product can be mounted on a panel with a thickness of 1.0 to 3.2 mm.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

B C For vacuum 0.0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 to 100 kPa -100 kPa 100 kPa For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13No.PS-OMG0004-D Dimensions PSE54(A)M3 M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision

If a single-solenoid valve is mounted on the standard wiring manifold, the output number for the B side valve is skipped. : Custom wiring for mixed mounting single-solenoid valves and double-solenoid valves can be specified with a Wiring Specification Sheet.

"Jumping" is a condition in which the cylinder operates without control at a speed that is higher than the control speed.

IDX-OM-W016-D Operation Manual Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V IDFA6E-23-A,C,K,L,R,T,V IDFA8E-23-A,C,K,L,R,T,V IDFA11E-23-A,C,K,L,R,T,V IDFA15E1-23-A,C,K,L,R,T,V Please read this manual prior of using the air dryer. Keep the manual readily available for reference.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.