OUT2: Red Response time 1s or less Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits) Note 3) Hysteresis 12 to 24VDC (ripple 10% or less) Power supply voltage 70mA or less Current consumption 1000VAC for 1 min. between external terminal block and case Withstand voltage 50M (500VDC) between external terminal block and case Insulation resistance 1000Vp-p,
Port size Rc1/4, NPT1/4, G1/4 (ISO1179) Letter height 10mm M12 connector Lead wire with M12 connector (5m) 2 types: Straight and right angle Functions Key lock Anti-chattering Unit conversion (fixed with SI units inside Japan) Display calibration Zero clear Straight Right angle ISE70 ISE75 ISE75H MPa MPa MPa OUT1 OUT1 OUT1 Model U P DOWN U P DOWN U P DOWN SET SET SET Gray Orange Solid
The graphs are based on operation using an P/A DC power input type driver with halfstep energization.
When a large number of valves will be operated simultaneously, use type B (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides. Note 2) The value is for manifold base mounting (5 stations). 2 position type with single action. Note 3) The weight W is the value for the manifold only.
When a large number of valves will be operated simultaneously, use type B (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides.
3 Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C
From the View menu bar "parameter (A)" please click on the "parameter setting (P)". "Parameter Settings" screen will be displayed. Please click on Read". 6.3.3 Parameter setting method Please set the parameters for each actuator. Refer to "LECSS Operation Manual,chapter 5 for details of each parameter.
Alarm Detection (p.81) in operation manual Card Motor Controller (Step Data Input edition). Caution Ensure the alarm history is cleared only after taking corrective action in response to the alarms.
DC24 V10% DC24 V10% DC(+) DC(-) 8 / / 9 () 10 / 5 m / 11 10 1015 "-M" ( ) (kPaMPa) "-M" 12 SI kPa,MPa -49NO.ZK2-OM00801-B No. 13 14 A () 15 () / ( ) () -50NO.ZK2-OM00801-B 80mA 3.5 F.S. 1 1 F.S. -51NO.ZK2-OM00801-B 100.0-100.0 kPa 105.0-105.0 kPa 500 kPa 0.1 kPa DC24 V 10(p-p)10() 40 mA NPN PNP OUT1OUT2 80 mA DC26.4 V 2 V (80 mA ) 2.5 ms (20,100,500,1000,2000 ms ) 0.2F.S
System Error If the error can not be reset after the above measures are taken, then please contact SMC. -54NO.TQ1050188-OM002 Specification Specifications Rated pressure range 100 to -100 kPa Set pressure range 105 to -105 kPa Proof pressure 500 kPa Smallest settable increment 0.1 kPa Applicable fluid Air Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (Protected against reverse
FA 3m 27 (M230) 2 O 1 No.ZB-OM00301 Assy ZB1ZS A M G A E 0.0~-101.0KPa G (2m) F -100.0~100KPa ZS-39-5G A NPN2 B PNP2 1) M SI2) P (psi)1) 1) (M230) 2 2)kPa O 1 V Assy 45 2 V Assy 45 (V Assy ) A ) 28 - No.ZB-OM00301 A R R Nm 0.0540.08 R R ON OFF R 29 - No.ZB-OM00301 3 P911 Nm 0.075~0.096 M2 / 3 Assy Assy / / O (/) O 30 - No.ZB-OM00301 [L/min(ANR)] V
P Peak value display Displays the maximum vacuum pressure reached up to that moment. Pilot valve for air supply The solenoid valve which turns on and off the ejector. (This pressure switch outputs signal to the supply pilot valve) PNP (open collector) (output) The switch that uses the PNP transistor for output.
(REFRIGERANT) IDF60-20) W R 0001 (2018 4 ) W R 0001 2018 2019 2020 2021 W X y Z 1 2 3 4 o P Q R o 1 Z 12 A Z IDF60/70/80/90 Series 1-5 IDX-OM-W093 1.3 HFC 1-5 IDF60/70/80/90 Series 1-6 IDX-OM-W093 1.4 / 1 1.5 () IDF60/70/80/90 Series 1-7 IDX-OM-W093 IDF60/70/80/90 Series 1-8 IDX-OM-W093 2 2.1 IN OUT (ONOFF ) 6-4 6-4 IDF60,70,80,90-20 IDF60,70,80,90-30 AC200V AC200V L1 L2
Front Structure of the product number W R 0001 (2018 April) W R 0001 Year Symbol Note Month Symbol Note Serial No. 2018 2019 2020 2021 W X y Z Repeated from A to Z in alphabetical order 1 2 3 4 o P Q R Repeated from A to Z in alphabetical order, with o assigned for January and Z for December. 1.2 Hazard classifications/ Hazard Warning Labels IDFC60/70/80/90 Series 1-4 IDX-OM-U010 Chapter
(REFRIGERANT) IDFC60-23 W R 0001 (2018 4 ) W R 0001 2017 2018 2019 2020 V W X Y A Z 1 2 3 4 o P Q R o 1 Z 12 IDFC60/70/80/90 Series 1-4 IDX-OM-W095 1.3 HFC 1-4 IDFC60/70/80/90 Series 1-5 IDX-OM-W095 1.4 / 1 1.5 () IDFC60/70/80/90 Series 1-6 IDX-OM-W095 2 2.1 IN OUT (ONOFF ) 6-4 6-4 L N PE 3-5 IDFC60/70/80/90 Series 2-1 IDX-OM-W095 () IDFC60/70/80/90 Series 2-2 IDX-OM-W095 3
Front Structure of the product number W R 0001 (2018 April) W R 0001 Year Symbol Note Month Symbol Note Serial No. 2018 2019 2020 2021 W Repeated from A to Z in alphabetical order 1 2 3 4 o P Repeated from A to Z in alphabetical order, with o assigned for January and Z for December.
Q IDFA6E Rc3/4 270 455 498 31 42 283 80 230 32 15 240 80 275 275 15 6 2 6 6 3 (50/60Hz) AC200/200,220V GFCI R R L N PE TB ILS V V EDV OLR PTC PE CM PE FM1 PRS P FM2 PE CM FM 12 OLR PTC PTC ILS PRS TB PE GFCI EDV 6 3 6 6 4 2 6 4 7 A A 7 1 7 2 A m 3/h(ANR) 1) (50/60Hz) 0.32/0.375 10 1ANR 65% 2 7 3 7 1 8 C 8 C 8-1 8-2 1) 2) 8-3 8 1 9 G G 9-1 9 1 10 H 10 H 10
(Refer to Dimension diagram on P.19.) The piping of this product should be horizontal (drain exhaust should vertically face downwards.) If it is mounted inclined, laterally or upward/downward, the separated drainage will be splashed over the outlet. It may cause the operation failure of the auto drain.
SU P. PRESS. 1. 0 M Pa O U TPU T PRESS. 0. 0050. 2 M Pa M AD E I N J APAN So G No.
Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at