SMC Corporation of America
Elite Part Number Search
Search Results "VVEX2-1-3-02"

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, CB, AS 1/8INCH STANDARD (PT), .19682 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g)

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, D7, AS 1/4INCH EUROPEAN, .25300 lb

This is a legacy product, and replaced byAV2000-02-5DB-A, VALVE, SOFT START 1/4, VALVE, AV SOFT START UP BODY PORT, FA, AV BODY PORT 1/4 PT, .88184 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread: R, Port Size: 02 (1/4), Applicable Tubing: 11 (ø3/8"), Seal Method: None

Size: 20, Model: Air Filter + Regulator + Lubricator, Thread: Rc, Port Size: 02 (1/4), Float Type Auto Drain: w/o Auto Drain, Attachment: S (Pressure Switch), Option 1: None, Option 2: J (Drain Guide Body Size 20 1/8; Drain Guide Body Size 30, 40 1/4), Option 3: None

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 10 (ø10), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 03 (ø5/32), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 07 (ø1/4)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 07 (ø1/4), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 09 (ø5/16)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 09 (ø5/16), Sealant: S (with Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 11 (ø3/8), Sealant: S (with Sealant)

Size: 3 (1/4), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 1 (0.05 to 0.7MPa), Relief Function: 1 (Relief), Thread: A (Metal Gasket Seal Fitting), Port Size: 02 (Rc1/4)

Size: 3 (1/4), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 1 (0.05 to 0.7MPa), Relief Function: 1 (Relief), Thread: A (Metal Gasket Seal Fitting), Port Size: 02 (Rc1/4), Direction of Gauge Port: R (Right)

Size: 3 (1/4), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 1 (0.05 to 0.7MPa), Relief Function: 1 (Relief), Thread: N (NPT), Port Size: 02 (Rc1/4), Direction of Gauge Port: R (Right)

Size: 3 (1/4), Cleaning Grade: 1 (B Grade: Ultrasonic Cleaning), Pressure Setting: 1 (0.05 to 0.7MPa), Relief Function: 1 (Relief), Thread: N (NPT), Port Size: 02 (Rc1/4)