This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The AMG series water separator is installed on the air pressure line to remove water drops from compressed air. It is available in 7 sizes with a variety of optional combinations to meet your application requirements. Water Separator w/possible modular connection, Water removal rate:? 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide,
The AMG series water separator is installed on the air pressure line to remove water drops from compressed air. It is available in 7 sizes with a variety of optional combinations to meet your application requirements. Water Separator w/possible modular connection, Water removal rate:? 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series AF modular style air filter is a cost effective, clean looking solution to your filtration needs. Its' modular design allows connection with other SMC air preparation equipment. The series is available in six size options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides
Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.
fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display
Fig. 9-22 Cooling Capacity (HRL100/200-W-40-T2 CH2) HRL Series 9.4 Cooling Capacity 9-19 HRX-OM-X037 Chapter 9 Documents 9.5 Pump Capacity 9.5.1 HRL100-A/W-40 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig.
60 B A 50 H 50 W(kg) A/H W(kg) 40 40 30 30 20 20 10 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 LECPA V(mm/s) V(mm/s) LES40 Horizontal Transfer LES40 Vertical Transfer B 60 (2) Servo motor (24VDC) Ball screw drive 60 B A 50 H 50 A/H W(kg) W(kg) 40 40 30 30 20 20 10 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 V(mm/s) V(mm/s) LEFS16A LEFS25A Model Stroke [
BAND TEMP SP READY TIME TEMP PV TEMP READY display/output TEMP READY not display/not output Figure 8-7 BAND/READY Function Examples of Setting TEMP SP: 20C BAND: 2C READY TIME: 60 sec. RDY is displayed on the operation touch panel 60 sec. after TEMP PV value becomes 18C to start output by communication. Necessary condition is that TEMP PV value after 60-sec. is 20+/-2.0C or less.
CS1 Trunnion (mm) Stroke range Bore (mm) TV TT TS TR TH TF B TDe8 TE Front Rear 0.025 0.047 0.025 0.047 0.032 0.059 0.032 0.059 0.032 0.059 0.032 0.059 20 25 32 40 50 63 3.2 3.2 4.5 4.5 6 8 28 33 40 49 60 74 39 43 54.5 65.5 80 98 25 30 35 40 50 60 5.5 5.5 6.6 6.6 9 11 Up to 200 Up to 200 8 10 12 14 16 18 35.8 39.8 49.4 58.4 72.4 90.4 38 45.5 54 63.5 79 96 10 10 10 10 20 20 Up to 300 Up to
70 60 70 Gripping point L (mm) Gripping point L (mm) MHR2-30/MDHR2-30 MHR2-30/MDHR2-30 80 80 Pressure 0.6 MPa 0.6 MPa Pressure 70 70 F F 0.5 MPa 0.5 MPa Gripping force (N) Gripping force (N) 60 60 50 50 0.4 MPa 0.4 MPa 40 40 0.3 MPa 0.3 MPa 30 30 0.2 MPa 0.2 MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Gripping point L (mm) Gripping point L (mm) 12-5-7 8 Series MHR2/MDHR2 Construction
Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400
0.5MPa 0.5MPa 60 60 Holding force (N) Holding force (N) 50 50 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 30 30 0.2MPa 0.2MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Holding point L (mm) Holding point L (mm) 2.3-6 Series MHR2/MDHR2 Construction MHR2 !
Symbol Rated pressure range and accuracy Part no. 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC With pressure sensor (0 to 101 kPa, accuracy 2% F.S.) With pressure sensor (0 to 101 kPa, accuracy 1% F.S.) With pressure sensor (100 to 100 kPa, accuracy 2% F.S.) With pressure sensor (100 to 100 kPa, accuracy 1% F.S.)