Thread R(PT) Port B min. port size Weight (g) D2 L1 L2 L3 P A Q1 Q2 M1 M2 1 8 1 4 3 8 6 4 KM14-04-06-01S-3 13 14 17 18 13 10.4 38.2 16 9.9 17 68 71.5 73.5 19 26 39 4.5 KM14-04-06-02S-3 12.8 10.4 KM14-04-06-03S-3 64 65.5 67.5 1 8 1 4 3 8 8 4 KM14-04-08-01S-3 31 69.5 70.5 71 73.5 76.5 77.5 17 19 15.5 10.4 38.2 16 11.1 18.5 39 6 KM14-04-08-02S-3 15.2 10.4 KM14-04-08-03S-3 1 8 1 4 3 8 8 6 KM14

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 * Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08

When the ambient Continuous monitoring temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

03 04 VVQ5000-P-1(Plug-in type) VVQ5000-P-5(Plug lead type) 179 (Plug-in type) 133 (Plug lead type) 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: Rc 3/8 04: Rc 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug llead type Individual EXH spacer 03 04 03 04 VVQ5000-R-1(Plug-in

AN40-04 AN40-04 AN40-04 AN40-04 AN40-04 Air operated type AN40-04 AN40-04 AN40-04 AN40-04 AN40-04 AN40-04 VXF(A)25BA(B) VXF(A)26BA(B) VXF(A)26CA(B) VXF(A)26DA(B) VXF(A)27BA(B) VXF(A)28BA(B) Note) Spring is shipped together with the product, but not assembled. 10 Series VXF2 Dimensions: Direct piping type VXF21A<<

KKA6P-04 F-1 Rc1 / 2 Rc1 / 2 KKA6S-06F-1 KKA6P-06F-1 Rc3 / 4 Rc3 / 4

Applicable model 84 84 03 FGD-CV002-04 06 03 FGD-CV003-04 06 03 FGD-CV004-04 06 03 FGD-CV001-04 06 32 32 FGDT/F FGDT/F FGDC/E FGDC/E Note 1) Same as standard product except for cover assembly Note 2) 03, 04, and 06 indicate the relevant port sizes (Rc3/8, 1/2, 3/4).

) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 2.7 2.7 2.7 5.1 5.1 5.0 10.3 10.3 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 22.2 27.7 34.5 43.9 49.1 61.1 77.1 90.0 56 56 56 76 76 76 101 101 71 71 71 104 104

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".

7) IS1000M-60 IS1000M-50 Y510-(02) 03 IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E100-M5 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure

How to Order Sub-plates 04 P VQ5000 Electrical entry Port size Replacement of pilot valve assembly (Voltage) Refer to pages 2-6-40 to 2-6-41 for pilot valve assembly part numbers. Refer to page 2-6-3 for replacement method. 04 Rc 1/2 Porting specifications P S Plug-in conduit terminal Plug lead Note1) For bottom ported, port size is Rc 1/2.

2 Without sub-plate 1 4 3 8 1 2 4 JIS Symbol Note) A M5 01 02 02 03 04 04 06 10 10 12 14 20 Note) M5 1 8 1 4 1 4 3 8 1 2 1 2 3 4 1 Note) Note) 3 Body ported 5 1 1 11 4 7 1 4 11 2 1 2 2 9 Note) Only bracket or foot may be mounted. 14-10-2 3 E-P HYREG Series VY1 Standard Specifications 02 03 04 04 06 10 02 03 04 VY1A0 0 1-M5 VY1B0 0 1M 0 5 1 VY110 0 10 0 1 2 VY120 0 10 0 1 2 VY130 0 1VY140

7) IS1000M-60 IS1000M-50 Y510-(02) 03 IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E100-M5 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure

M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.