Then, Sending completed(IN Data n+19[bit 0]) is changed from 1 to 0. 1 3 6 Operation command 2 Data (Position, speed) 4 Sending Sending completed Operation 5 INP 35 - 11. 4. Data writing mode This is the mode that the step data of the controller(LEC6) can be changed through the gateway unit.
valves 32 outputs Valve output Applicable valve series Solenoid valve with surge voltage suppressor of 24 VDC and 1.0 W or less (manufactured by SMC) Output setting during communication fault HOLD / CLEAR / Force ON Protection Short circuit protection Enclosure IP67 (manifold assembly) 1 Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35
. : Refer to page 35 for the seal cap. -11No.EX-OMO0030-E Power supply connector layout PWR: M12 5-pin plug, A-coded (SPEEDCON) No. Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.
Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.
Fix the mounting brackets (bracket plate) by the attachment hexagon socket head cap screw (M3 x 35:2 locations), paying attention to avoid the gap between each block. (0.6 Nm) Installation to the DIN rail When mounting the SI unit and output blocks on the DIN rail, mount the DIN rail mounting bracket on the bracket plate, and mount it on the DIN rail. Refer to the assembly drawing.
For EX250-IE2/3(M12/8, 4 inputs), four bits are used for input. -45No.EX-OMK0006-C Specification Specifications General specification Item Specification Operating ambient temp. -10 to +50 oC Operating ambient humidity 35 to 85% RH (No dew condensation) Storage ambient temp. -20 to +60 oC Withstand voltage 500 VAC for 1 min.
(Between FG and external terminal) Insulation resistance 2 M or more (500 VDC between FG and external terminal) Environment Operating temperature: 0 to +55 oC (when 8 outputs are used) 0 to +50 oC (when 16 outputs are used) Ambient temperature Storage: -10 to 60 oC Ambient humidity 35 to 85%RH (no condensate) Pollution degree Pollution degree 3 Operating environment No corrosive gas Standard
protection of surge voltage of 24 VDC 1.5 W (SMC) Power supply (output) 24 VDC Class2, 2 A Output for com. error HOLD/CLEAR/Force ON Protective function Short circuit protection Enclosure IP67 (with manifold assembled) 1 Operating temperature range -10 to 50 oC (Max. surrounding air temperature rating: 50 oC) 2 Environment Storage temperature range -20 to 60 oC Operating humidity range 35
70 75 70 60 11 16 100 3.2 45 80 56 M6 x 1 Depth 8 6 Width across flats 32 AV5000-06,10-5 to 6G(Z)-A -28- DIN terminal: AV00--D/Y--A (mm) Dimensions Standard specifications Port size A B C D E1 E2 G H J Model 1(P) 2(A) 3(R) AV2000-02-1 to 6D/Y(Z)-A 1/4 1/4 1/4 66 97 47 24.5 20 20 33 Width across flats 22 30 AV3000-03-1 to 6D/Y(Z)-A 3/8 3/8 3/8 76 97 50 29.5 20 20 38 Width across flats 24 35
(Refer to page 35) 4. Channel parameter setting Parameters of each channel are set. (Refer to page 41) -33No.EX-OML0011-C 1. Selection of parameter Explanation of screen a) Name of each parameter to be set b) The next parameter is displayed with the and buttons. c) Parameters that can be set in each unit only. d) Parameters that can be set in each channel only. 2.
Assembly object (0x04) Attributes Unsupport Object class Services Unsupport Section Information Number of maximum Type Static I/O 1 ID Meaning GET SET Value 0x01 Number of Members in List Object instance Attributes 0x02 Member List 0x03 Data Cord Meaning Parameter option Services 0x0E Get_Attribute_Single Digital I/O slave (Output) Data Instance Byte offset bit7 bit0 +0 7 6 5 4 3 2 1 0 35
But when return to the Enable DHCP from Disable BOOTP/DHCP, it is possible to set the new IP address from BOOTP/DHCP server. 34 5.2 PLC setting (Configuration) . 35 5.3 Setting of EtherNet/IPTM using RSLogix5000TM . 36 6.
Two mounting screws (M2X30) and one O-ring are included. 35 - Doc. no. ZB-OM00201-B (14) Pressure switch assembly for vacuum If only the lead wire with connector is required order part number ZS-39-5G.
and terminology 10 Common Specifications 12 EX510 GW Unit Summary of Product Parts 13 Mounting and Installation 14 Installation 14 Wiring 15 Setting 20 Specifications 24 Specifications 24 Dimensions 25 SI Unit Summary of Product Parts 26 Mounting and Installation 28 Installation 28 Wiring 29 Setting 33 Specifications 33 Specifications 33 Dimensions 34 Output Unit Summary of Product Parts 35
Note5) The following combinations are available: A+G or B+G F Note6) "J" has a terminal box, but it is non-explosion-proof specifications. 30 12.Attached Drawing D 31 32 33 34 35 36 37 Revision history Revision D 10/ 7/2020 Revision E 25/12/2020 Revision F 25/ 4/2022 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com
D-P3DW Auto switch Figure-17 Auto switch D-P3DW model Bore size A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 * Auto switch mounting bracket is necessary for mounting the D-P3DW type. If you order the switch alone, the auto switch mounting bracket can be ordered using the part number below.
mode 22 Setting procedure of initialize mode 23 Function selection mode 26 F_1 Input procedure of the Set value of instantaneous output 27 F_2 Input procedure of the Set value of instantaneous output (Auto-preset) 28 F_3 Input procedure of the Set value of accumulated output 29 Key-lock function 31 Maintenance 32 Troubleshooting 33 Cross-reference for troubleshooting 33 Error indication 35
1) Note 2) Note 3) 1 to 5 1 to 4.8 1 to 3.9 1 to 2 Positioning resolution [ m] 30 1.25 30 1.25 30 1.25 5 1.25 Positioning operation Positioning repeatability [ m] Note 4) Note 5) 90 5 90 5 90 5 20 5 Measurement Accuracy [ m] Note 4) Note 5) 100 10 100 10 100 10 40 10 Maximum speed [mm/s] Note 6) 400 Operating temperature range [oC] 5 to 40 (No condensation) Operating humidity range [%] 35
Input the RESET signal. -35- No. Phenomenon Cause Countermeasure 1) Added excessive external force 2 Operation not completed Operate within the specified range.