Refer to pages 15-18-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-1-10 to 11 for Precautions on every series. Caution 1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Also, the surge voltage pressure must be under the maximum operating pressure.
NBR 2 JIS B 2401, P8 O ring NBR 2 JIS B 2401, P5 O ring NBR 1 JIS B 2401, P3 O ring NBR 2 -9- -10-10- -11#1 -11-11- Revision A Format change and content review B Drawings update 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the
F G H [Tightening torque] No.LZ-OM00401 B (1/3) Electric Cylinder LZC series L[]ZC[]3[] 1.5 8 M4 x 0.7 x 6 deep [0.75Nm ] L[]ZC[]5[] 3 13 M5 x 0.8 x 8 deep [1.5Nm ] L[]ZC[]3[] M4 screw 0.75Nm M4 screw 0.75Nm L[]ZC[]3[] 4.5 8 2 7.5 11.5 12 L[]ZC[]5[] 6.5 13 3.2 10.7 16.7 15 L[]ZC[]5[] M5 screw 1.5Nm M6 screw 2.6Nm Model no.
3!7 Rod Cover assembly MHL-A1007 MHL-A1607 MHL-A2007 MHL-A2507 MHL-A3207 MHL-A4007 Finger assembly Pinion assembly MHL-A1008 MHL-A1009 MHL-A1608 MHL-A1609 MHL-A2008 MHL-A2009 MHL-A2508 MHL-A2509 MHL-A3208 MHL-A3209 MHL-A4008 MHL-A4009 w!8@1@5 tyu@3@4 Order 1 pinion assembly per one unit.
-2VT307N-OMV0001 / *3) 1 1.5 *3)1 1 () [] -3VT307N-OMV0001 VT307 3 / / () () ( ) () C-R ( ) C-R DC 3% , () ( AC 15% ) (SSR)AC 1) (C-R ) OFF 2)() 1V ,-10 1 DC N.O.() 3 4 No.VT307N-OMV0001 VT307 3 / () DC 30N 1) 2)1 ()ISO VG32 (SDS) 1 Nm Rc 1/8 35 Rc 1/4 812 5 No.VT307N-OMV0001 VT307 3 / () () 30 ( ) , 1 ()ISO VG32 6 No.VT307N-OMV0001 VT307 Series/ DIN 1) ()
Note 4) The values in the table are not warranted, but the measured values. 393 Soft Fluoropolymer Tubing Inch Size Series TID Model/Specifications Inch size Model Size TID01 TID05 3/16" 4.75 TID07 1/4" 6.35 TID11 3/8" 9.53 TID13 1/2" 12.7 inch mm 1/8" 3.18 Tubing O.D. 0.124" (1/8") 0.156" (5/32") 0.25" (1/4") 0.374" (3/8") 0.086" inch Tubing I.D. mm 8 m 16 m 2.18 3.15 3.95 6.33 9.5
Clamping range : Under +3 0 Angle tolerance of the clamp : -0.25 to +0.25 Figure 1 (3) Be sure to use a speed controller, and make adjustments according to the following conditions. Unclamping to clamping: 1 second or more. Clamping to unclamping: 1 second or more.
Step 1 Step 2 Step 3 Step 4 Step 20 Step 5 . . . . . . . . . . . . .
No. 1 2 3 4 5 Note Material Aluminum alloy Aluminum alloy Aluminum alloy EP Description TSUBAKI CABLEVEYOR Cable side cover Mounting plate Cable flange End cap Construction Precautions on handling of the TSUBAKI CABLEVEYOR 1.
) 2 (same surface) 2 (different surfaces) 1 3 (same surface) 3 (different surfaces) 2 (same surface) 2 (different surfaces) 1 90 55 50 15 10 105 60 60 15 10 105 65 65 15 10 115 75 65 25 15 35 10 5 45 10 5 40 15 10 45 5 5 30 5 5 55 15 10 40 15 10 60 15 15 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 D-C7 D-C80 D-A7H D-A80H D-H7 D-H7W D-H7BAL D-H7NF Band mounting D-A79W Rail mounting D-F7
2 ID 85 130 Rc 1/2 440 260 560 540 297 330 315 470 325 530 IDUS6E 315 130 605 540 Rc 3/4 325 355 515 485 325 575 285 110 AMG Note: The diagram above is drawn base on IDUS3E dimension with scale 1:6.
Single MSU 90 3 90 Double 1 90 90 CRQ2 10 180 90 1 MSQ 2 90 3 Note) If the piping is longer than the above tube length, the IDK-200 may be necessary. 3 Moisture Control Tube Series IDK Model Selection Selection Procedure Check the presence of condensation. 1 Select the length of moisture control tube for the condensation area. 2 (1) The presence of condensation can be verified by the dew
VNl VQ 4.3-3 2 Port Solenoid Valve SeriesVQ20/30 For Dry Air, Pilot Operated Single Unit How to Order Valve VQ A C6 2 1 1 1 G Series/Orifice Option Series VQ20 VQ30 Effective orifice 3.4mm 4.8mm : None Symbol 2 3 F: With bracket Switching N.C. (A) 2 L: L style (VQ20 Only ) 1 1 (p) Note) Consult SMC if N.O. is desired. Note) If ordering both options, indicate "LF".
Doc. no.LV50***-OMZ0015 PRODUCT NAME Vinyl Chloride Air Operated Valve MODEL / Series / Product Number LVP series Contents 1. Safety Instructions P2 2. Dimensions P4 3. How to Order / Specifications P6 4. Applicable Fluids P7 5. Trouble Shooting P8 1 - 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
) [90.5] 2-4.5 Mounting hole Manual override Manual override 87.5 (111.5) [90.5] 300 (Lead wire length) G 1/2 (Cable 8 to 10) 3-Rc , 1 4 3 8 3-Rc , 1 4 3 8 ( ): DC [ ]: AC, with indicator light 4-16-3 4 Series VS3115/3110 Manifold Specifications Specifications Manifold type Max. number of stations B mount 10 stations Port location/Port size P A E P A E Port direction Applicable valve model
Also, BBA2 is included when a auto switch alone is shipped. 3 Plate Cylinder with Lock Series MLU Construction !4 !7 !0 !4 @1 u q !3 !2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !
PF2W2 series Power and output socket Socket for the power and output connection. 1: In window comparator mode, the hysteresis is fixed at 3 digits. When setting, allow 7 digits or more between Set point 1 and Set point 2. 2: When Set point 1 = Set point 2, chattering may occur.
Prm_Req 1 when the SI unit setting is rewritten by the master Diag. Deactivated 1 when SI unit is stopped Reserved Diag. Stat_Diag 1 when it has a diagnosis Diag. Sync_Mode 1 when Sync command is received Diag. WD_on The watchdog is in active state Diag. Freeze_Mode 1 when Freeze command is received Byte2: Station Status 3 Bit 7 0 0 X X X X X X X Reserved Diag.
RSQ*-OM0080Q PRODUCT NAME STOPPER CYLINDER MODEL / Series / Product Number RS(D)Q12 RS(D)Q1650Z Contents Safety Instructions P.2,3 P.4 P.4 P.4 P.4 P.4 P.5 P.6 P.8 P.9 P.10 P.11,12 1. Specifications 1-1. Cylinder specifications 1-2. Single acting (Spring extended) spring force 2. Internal diameter and standard stroke 3. Operating air 4. Speed adjustment 5. Directional control 6.
Description Material 1 Element 2 Cover PBT 3 O-ring HNBR 4 Clean One-touch fittings PP, EPDM, Stainless steel 5 Bracket PBT Replacement Parts No. Description Material Note 1 Bracket set SFD-BR100 With 2 countersunk head screw (M3) 5. Maintenance The element of this product cannot be disassembled or replaced.