Body Type: T (Body Ported), Valve Option: E (Continuous Duty), Voltage: 3 (110VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light w/Surge Voltage Suppressor), Port Size: 02 (1/4, 8A), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 5 (24 VDC), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: S (with Surge Voltage Suppressor, Grommet Type Only), Port Size: 02 [1/4 (8A)], Thread Type: T (NPTF)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty Type, Semi Standard), Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 3 (110 VAC, 50/60Hz, Semi-Standard), Electrical Entry: G (300mm Lead Wire), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Side Piping), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Side Piping), Thread: T (NPTF)
Stations: 5 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 02 (Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: Standard, Attachment: T (T Spacer), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right->Left)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: CG (C + G), Attachment: T (T-Interface), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: T (T spacer), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 25, Thread: Rc, Port Size: 02 (1/4), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 1J (1 + J), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: T (T spacer), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: T (T spacer), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: T (T Spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 1 (2 Position Single), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Side Piping), Thread: T (NPTF)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
T Note1) EB LL Concentrated piping on right (CY1F10 to 25R--) KA KB HW EW GD GC 2-P (Hexagon socket head plug) Hexagon socket head bolt For adjustment bolt fixing ES 2-P (Piping port) EY HA EH KC GB KH H GB GA G GA HB KW N N Adjustment bolt A Z + Stroke Concentrated piping on left (CY1F10 to 25L--) KA KB EW 2-P Hexagon socket head bolt For adjustment bolt fixing HW ES (Piping port) 2-P (Hexagon
4 P 5 X4 PRR COM1 () X0 6 THR X1 THS2 THS1 CM L X2 OLR N PRS2 PRS3 MC1,2 X3 EDV PE P P THR THS1,2 24V TB1,2 T V V FM1,2 SWL PRR PRS1 PRS2 PRS3 PLC GFCI EDV IDFA100F150F 6 6 6.4 IDX-OM-U022 6.
B76 B73 I.C. 5V P P P P P P P P P P P P P P P P P 3 wire (Equiv.