Blanking plate assembly Blanking plate 437 AWG30, 40 Exploded View 2 Pressure gauge cover Stem assembly Handle (Convex) Pressure Valve assembly Pressure gauge assembly O-ring Valve spring Pressure adjustment guide Valve guide Planet gear A Clip Spanner flats Concave: 2 places Planet gear B Element Bonnet Mounting screws (4 pcs.)
entry P Port size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5 83 66 50 99 50 44 59 22 1/8 VCB21 M4 12.8 18 28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/
PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output PNP output 1 to 5V output 4 to 20mA output 25 65 26 28 Panel mount B Unit specification Nil M With unit switching function Fixed SI unitI (International System of Units) Note) Note) Fixed units: For vacuum/Low pressure: kPA For positive pressure: MPa Optional Part Nos.
SMC PRESSURE SWITCH PD PV 57 1 67 1 32.4 109 Approx. 300 Ejector RESET SET Supply valve Release valve V 21.2 Manual override Suction filter 1 2-4.6 (mounting hole) 1 5.6 1 8 1 10.2 123 1 4.6 1 8 SOL. c SOL. a Silencer SOL. b Interface A Light Suction filter Manual override Interface B Digital vacuum pressure switch M5 port PE (pilot valve exhaust port) M5 port PD (vacuum breaking pressure
8 7 12.7 9.6 12.3 28.6 25.8 25 22.2 AS121F-M5-23 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 17.3 17.3 3.2 22.1 8.4 22.1 9.3 AS121F-U10/32-23 AS121F-U10/32-03 10-32UNF 5/32" 10-32UNF 12.7 12.3 AS121F-M5-04 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 28.6 25.8 25 22.2 21.3 26.1 4 7 9.6 7 16.5 8 11.4 9.3 22.1 17.3 AS121F-U10/32-04 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 25 22.2 9.6 AS121F-M5
40 11-LEFG25-S 45 64 (102) 3H9 (+0.025 0 ) depth 3 4 x M5 x 0.8 thread depth 8.5 38 50 3.5 3H9 (+0.025 0 ) depth 3 A (Table traveling distance) L 51 (52) 10 10 58 38 48 38.5 (48) 26 24 n x 4.5 Vacuum port Rc1/8 48 120 F D x 120 (= E) B Dimensions [mm] Dimensions [mm] Model L A B n D E F 11-LEFG25-S-50 180 57 160 4 20 11-LEFG25-S-100 230 107 210 Model L A B n D E F 11-LEFG25-S-450 580 457
Auto Switch Proper Mounting Position (Detection at Stroke End) Reed auto switch Solid state auto switch D-A9 D-M9 D-M9W Hs Hs 22 B A 24.5 B A A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch. A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch.
IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when workpiece is vacuumed. Min.B: Maximum pressure value when workpiece is not vacuumed.
-04 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 8 17.3 22.2 7 9.3 22.1 9.6 4 25 25.8 22.1 28.6 9.3 17.3 AS121F-U10/32-04 AS121F-U10/32-03 5/32" 10-32UNF 10-32UNF AS121F-M5-06 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI Unit : torque = 1.5 Nm) 4 x M (Valve manifold: refer to valve manifold catalogue) Fig. 7-1 Required screws All manifolds are mounted using 8 screws (except VQC4000 which uses 7 screws). 25 No.EX##-OMY0004 7.1.1. Valve manifold connection Connect the valve manifold with the 2 screws on the SI Unit.
For IITV00-n Total weight (g) Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional.
The scale indication range is also printed on the to JIS B 4609-2008 Table 1. product.
Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years
Model MQR1-M5 MQR2-M5 MQR4-M5 MQR8-M5 MQR12-M5 Number of circuits 1 2 4 8 12 Operating fluid Air / Inert gas Seal structure Metal seal Guide structure Bearing supported Bearing supported at both ends Port size Male R1/8 Female M5 x 0.8 M5 x 0.8 Flow rate C[dm3/(s.bar)] b Cv characteristics 0.50 0.40 0.17 Lubrication Not required Min. operating pressure -100kPa Max. operating pressure 1.0MPa
5) Y V IDF100F V IDF125F V IDF150F B 1.3 IDF100150F-W 1 4 IDX-OM-Z004 1 3.6 5.2 (IDF100F, 125F) R OFF 5.2 L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6 M4 9.5mm 5.5mm M3 6.5mm 1.25mm 2 2 1.3 IDF100150F-W 1 5 IDX-OM-Z004 1 3.6 5.2 5.2 (IDF150F) R OFF L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6
AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.