(CN2SW) . 16 4.3 (LEC) . 17 5. . 19 5.1 CN4 . 19 5.2 CN3 . 19 5.3 CN1CONT . 19 5.4 CN2PC/TB . 20 .CN4 . 21 6.1 . 21 1 - 6.2 . 21 6.3 . 22 . 23 7.CN3 . 24 8.CN1IF (CONT) . 25 8.1 . 25 8.2 . 27 9.CN2TB/PC . 28 9.1 . 28 10.LED . 29 10.1 LED . 29 10.2 IF LED . 29 11. . 30 11.1 . 30 11.2 . 30 11.3 . 30 11.4 . 32 12. . 33 12.1 . 33 12.1.1 . 39 12.2 IF ( ) . 40 12.3 (IO ) . 41

Specifications 41 Dimensions 43 Accessories 46 -1No.EX-OME0015-F Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.

Operations . 39 8.1 Return to origin . 39 (1) Return to origin operation . 39 (2) How to command the return to origin . 40 8.2 Positioning operation . 41 8.3 Jog operation / inching operation . 42 (1) Jog operation . 42 (2) Inching operation . 42 8.4 Servo ON . 43 8.5 Response time for the controller input signal . 43 9.

Part number of auto switchD-A9D-A9V Unitmm B A (When detecting retracted stroke end) H H 1 H 2 3 (When detecting extended stroke end) 5st 10st 15st 20st 25st 30st 35st 40st 4 6 1 6 11 16 21 26 13.0 10.0 20.0 10 1 6 11 16 21 26 31 36 41 16.0 9.5 19.0 16 1 6 11 16 21 26 31 36 41 18.0 12.0 24.0 Part number of auto switchD-M9D-M9VD-M9WD-M9WV Unitmm B A (When detecting retracted stroke end) H

Maintenance 41 8.1. Maintenance 41 8.2. Replacement Procedure 42 9. Specifications 47 10. Port Layout 52 11. Exhaust/Flow Rate Characteristics 62 11.1. Ejector Exhaust Characteristics/Flow Rate Characteristics 62 11.2. Vacuum Pump Flow Rate Characteristics 64 11.3. Vacuum Release Flow Rate Characteristics 64 12. Limitations of Use 66 13. Troubleshooting 67 -1No.

(m) (n) 41 No. JXC-OMU0029-A 7.4 Test function The table below shows the difference between normal (f) (e) (c) operation and test function in manual mode. To start the test function, set the position switch (h) to "0" while the power LED (a) (a) is lights up (= Servo ON) in manual mode and the electric actuator stops, and press the set button (g) for 3 seconds.

As this product has pressure balanced construction, the exhausting direction is free. 8 XL*-OMI0013-B 5.Dimensions 26 41 K J 72 53010 OPERATION INPUT K J V L C B 39 C B 69 XLS-**-P*G (with control power supply) XLS-**-P*G () L G1/2 D XLS-**-** (without control power supply) DIN terminal (D) DIN( D ) XLS-**-** () E D F K2 J L 27010 J M 29010 J K 33 25 G1/2 G1/2 C G C C B B B A A Terminal (

9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1

Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 1.45 CFM / 41 LPM , 1.45 CFM / 41 LPM, Max Pressure: 35 PSIG / 2.4 bar , 35 PSIG / 2.4 bar, Max Vacuum: 22.4 in HgV / -760 mbar , 22.4 in HgV / -760 mbar, Voltage (DC): 12, Item Dimensions: Length: 7.17 in / 182 mm Width: 4.25 in / 108 mm Height: 4.68 in / 119 mm , Length: 7.17 in