SMC Corporation of America
Elite Part Number Search
Search Results "25A-ZSE20C-V-M-02-W"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Rc1/8, Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

XX W-AREA1 Stroke(-)to Stroke (+) of the basic parameter If W-AREA1 >W-AREA2, the alarm Parameter ALM will be activated.(However,no alarm is generated if W-AREA1= WAREA2= 0, the WAREA output will be turned OFF) XX W-AREA2 ORG Correct [Link Offset] Fixed value This is the fixed value for this driver.

-SPN2A EX245-SPN3A (WLH)mm 85127.589.5 85147.789.5 465 g 540 g PBT 8 128 64 IO-Link 32 (US1 ) 300 mA 200 mA (US1/US2) XD1/XD2 16 A 6 A DC24 V 20%/15% US1 DC19.2 V 6 A DC24 V 20%/15% US2 4 A 1.2 V(DC24 V ) US1-US2 JSY JSY300JSY5000 SY SY3000SY5000 VQC VQC2000VQC4000 32 DC24 V,1 W PNP() 7/8 5 )10A EX245-SPN3A 4AXD1/XD2 6A 37 No.EX-OMW0014CN-A . 6-2 () EX245

Valve power PWR(V) supervision Enable Disable Enable WARNING: If safe PWR(V) monitoring is required for the application or if PWR(V) diagnostic is disabled on the device PWR(V) failures must be managed externally by other means.

Evaporation thermometer V Dustproof filter provided as a standard accessory V All electrical components are located in the front of the product.

Drip failure can cause damage to the components that need lubrication. 0.04 0.02 0 0 2000 4000 6000 8000 Flow rate L/min (ANR) 51 Lubricator AL10 to 60 Construction AL10 AL20 w w e q q t IN OUT IN OUT y y r u u AL30, 40 AL50, 60 w w q t q e e t IN OUT OUT IN y r i r u y u Parts list Description Material Note No.

Item Specification Rated voltage 30 VDC Rated current Power supply: 4 A, Signal: 0.3 A Contact resistance 40 m (The conductor resistance of the cable 40 mm is contained.) Insulation resistance 1000 M Withstand voltage 1000 V Operating temperature range -30 to +55 oC EX9-CCM1 DCN4-BR4 (OMRON Corporation) HCN-A4SMUG+ (HONDA TUSHIN KOGYO Co., Ltd) etc.

PSE200A-(M) : NPN open collector 5 outputs + Auto-shift 1 input Max. 30 V, 80 mA Residual voltage 1.5 V or less PSE201A-(M) : PNP open collector 5 outputs + Auto-shift 1 input Max. 80 mA Residual voltage 1.5 V or less -17No.PS-OMW0005-C Pressure Setting Default settings When the pressure exceeds the set value, the switch will be turned on.

N P Q R S T U V W 1.6 E 230 VAC 2.3 M5 Z Other voltages 3.2 Brass 1.6 2.3 1/8 For other special options, refer to page 462.

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb

Description Even number 0 to 14 Odd number 1 to 15 1 Power supply (24 VDC) 2 (Input) 3 Power supply (0 V) 4.