Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: R (with Manual Override for Residual Pressure Release)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EMR (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Plug for Individual Supply, Blocking the Air Supply Passage to D Side + w/Manual Override for Residual Pressure Relea
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EMY (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Plug for Individual Supply, Blocking the Air Supply Passage to D Side + Vacuum "V" port Release to Atmosphere Type, C
), Pressure Sensor: T2 (-100 to 200 KPa)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: ER (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + w/Manual Override for Residual Pressure Release)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: MY (Plug for Individual Supply, Blocking the Air Supply Passage to D Side + Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EM (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Plug for Individual Supply, Blocking the Air Supply Passage to D Side)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: Y (Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)
.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor: T2 (-100 to 200 KPa), Option: E (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EY (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: M [Plug for Individual Supply, (Blocking the Air Supply Passage to D Side)]
), Pressure Sensor: T2 (-100 to 200 KPa), Option: MR (Plug for Individual Supply, Blocking the Air Supply Passage to D Side + w/Manual Override for Residual Pressure Release)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: MY (Plug for Individual Supply, Blocking the Air Supply Passage to D Side + Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: R (with Manual Override for Residual Pressure Release)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: Y (Vacuum "V" port Release to Atmosphere Type, Check Valve: 1 pc)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EM (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Plug for Individual Supply, Blocking the Air Supply Passage to D Side)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: EMR (Vacuum Break Flow Adjusting Needle Screwdriver Operation Type Long Lock Nut + Plug for Individual Supply, Blocking the Air Supply Passage to D Side + w/Manual Override for Residual Pressure Relea
), Pressure Sensor: T2 (-100 to 200 KPa)
), Pressure Sensor: T2 (-100 to 200 KPa), Option: MR (Plug for Individual Supply, Blocking the Air Supply Passage to D Side + w/Manual Override for Residual Pressure Release)