SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-R-P-N02L-W"

Model: 12 (Top Ported), Number of Cores: L1 (34), Lead Wire Length: 3 (3m), Valve Stations: 16 Stations, P,E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P,E Port Size: ø8 One-touch Fitting, Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 12 (Top Ported), Number of Cores: L1 (34), Lead Wire Length: 3 (3m), Valve Stations: 13 Stations, P,E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P,E Port Size: ø8 One-touch Fitting, Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 12 (Top Ported), Number of Cores: L2 (17), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P,E Port Size: ø8 One-touch Fitting, Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 12 (Top Ported), Number of Cores: L2 (17), Lead Wire Length: 3 (3m), Valve Stations: 5 Stations, P,E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P,E Port Size: ø8 One-touch Fitting, Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: A3N (Negative Common, 32 Outputs), Valve Station: 7 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block Assembly: R (External Pilot), P, E Port Size: ø10 One-touch Fitting, Mounting: D (DIN Rail Mounting w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: N (ø5/16"), Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: N (ø5/16"), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EB (EtherNet/IPâ„¢ - 16 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 8 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: N (ø5/16"), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: ø8, Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 12 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: ø8, Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: Positive Common (or None), Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size: N (ø5/16"), Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (Negative Common), Valve Stations: 12 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size (One-touch Fitting): N (ø3/8"), Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common (or None), Valve Stations: 16 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), P, E Port Size (One-touch Fitting): N (ø3/8"), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 9 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: R (External Pilot), P,E Port Size: ø12, Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 9 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: R (External Pilot), P,E Port Size: ø12, Mounting: D (DIN Rail Mounting, w/DIN Rail), DIN Rail Option: 10 (for 10 Stations; Longer Rail

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 7 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: R (External Pilot), P,E Port Size: ø12, Mounting: D (DIN Rail Mounting, w/DIN Rail)

Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: VA (CC-Link - 32 Outputs - Connector M12), SI Unit Ouput Polarity: Positive Common, NPN, Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: R (External Pilot), P,E Port Size: ø12, Mounting: D (DIN Rail Mounting, w/DIN Rail), DIN Rail Option: 3 (for 3 Stations; Longer Rail than Total

Model: 12T (Top Ported), Type: None, Valve Stations: 2 Stations, P,E Port Entry: D (D Side), SUP/EXH Block Assembly: R (External Pilot), P,E Port Size: N (ø1/2" One-touch Fitting), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

M AX.SUP.PRESS. 1.0 M Pa OUTPUT PRESS. 0.0050.2 M Pa M ADE I N J APAN G So No. o S o1 T P2 U Q3 V R4 W Z12 -6- 5 (1) 1/4 1214 (2) (3) (4) -7-7- (1) (2) (3) (4) 1 2 3 (1) (2) 3 (3) 1 3 1 (4) P.5 0 (5) 0 -8- (1) (2) (3) 21Nm (4) (ONOFF (5) 79Nm (6) (7) (1) (AF ) AMAFM (2) 1( 2 1.5 (1) -9- 6. (1) 1 1.5 (2) , (3) a. b. c.

If the piping diameter is reduced, it may lead to insufficient flow of supply air, reduction of suction flow and reduction in the vacuum pressure. 1 The values indicating characteristics are representative values, and may vary depending on the atmospheric pressure (weather, altitude, etc.). 2 Supply pressure: 0.45 MPa Construction Model Selection Caution q t w r e y 1.