SMC Corporation of America
Elite Part Number Search
Search Results "IZS40-580Z-07B"

S coupler series KK employs a unique connection method. A slim body design and large effective area are achieved with a construction that does not use steel balls or valve springs and therefore does not restrict the flow path. Together with a reduction of the body size, pressing parts and resin parts are used to achieve an overall weight reduction. Plug and socket variations: male and

The ION/HV LED on the front panel turns ON (green) during normal discharge.
When the LED is ON (red), this indicates a high-voltage error has occurred.
The main cause of this is usually foreign matter or water droplets adhering to the emitter (electrode needle).
Remove the cartridge and clean the emitter after stopping the power supply and air supply.
For details on how to clean