A Dimensions except A, L and L1 are the same as rod side flange style.
closed center: VFR630 -F(Z) 3 position exhaust center: VFR640 -F(Z) 3 position pressure center: VFR650 -F(Z) 0 1 0 1 0 1 2 position double: VFR620 -F(Z) 263 3-2.3 146 93 (Electrical entry) 45 117 A B A B 72 90 108 PE EA EB PE P Manual override 170 186 4-9 (Mounting hole) (Non-locking) G 1/2 Light/Surge voltage suppressor (For FZ) Other dimensions are the same as the single type. 3-5-97
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
Tightening torque for terminal: 0.6 Nm Series VFS4000/5000 Model Terminal block marking A + A side A side A A side A side B + B VFS 100 VFS 200 VFS4 00 VFS5 00 4 5 4 5 B side B side 3 4 3 4 A side A side B side B side Applicable terminal: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M There is no polarity.
B port C port A port A C B Stroke B A SA + Stroke A SB + Stroke B Z + Stroke (A + B) B A C 4) Cylinder retraction When the air pressure is supplied from the (mm) Bore size SA SB Z 10 31.5 53 112.5 16 33 53 114 port, the rod retracts completely. Stroke B Stroke A Stroke A or Stroke B operation can be made individually. * Dimensions except mentioned above are the same as standard type.
ND hole H10 Axis d9 MM NX2 H A L R2 U2 Z (Min.)
closed center: VFR630 -F(Z) 3 position exhaust center: VFR640 -F(Z) 3 position pressure center: VFR650 -F(Z) 0 1 0 1 0 1 2 position double: VFR620 -F(Z) 263 3-2.3 146 93 (Electrical entry) 45 117 A B A B 72 90 108 PE EA EB PE P Manual override 170 186 4-9 (Mounting hole) (Non-locking) G 1/2 Light/Surge voltage suppressor (For FZ) Other dimensions are the same as the single type. 3-5-97
Clearance for maintenance G Drain 2 x P1 (Port size) A C R B Q V IN OUT Panel fitting dimensions Panel fitting dimensions H Y Y W W Pressure gauge (Option) IN IN OUT OUT 2 x P2 Z Z (Pressure gauge port size) Plate thickness AW30-A to AW40-06-A: Max. 8 Plate thickness AW10-A: Max. 3.5 AW20-A: Max. 4 Clearance for maintenance G 2 x P1 (Port size) Drain A Applicable model AW10-A/AW20-A AW20-
11.5 5 to 50 L H J P Q QA R S SA T W Y Z Model ZC(D)UKD16 ZC(D)UKD20 ZC(D)UKD25 ZC(D)UKD32 ( ): In the case of a mounted auto switch.
28.5 30 32.5 B 9.5 20.5 23.5 25 29 30.5 33 B 6.5 17.5 20.5 22 26 27.5 30 A 23.5 27.5 26.5 34 34 41.5 45 A 28.5 32.5 31.5 39 39 46.5 50 A 20.5 26 25 32.5 32.5 40 43.5 A 23 27 26 33.5 33.5 41 44.5 A 23.5 27.5 26.5 34 34 41.5 45 A 20.5 24.5 23.5 31 31 38.5 42 A 24.5 30 29 36.5 36.5 44 47.5 20 32 40 50 63 80 100 Note) Adjust the auto switch after confirming the operating conditions in the actual
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/o Connector, Surge Suppressor: None, Manual Override: Push-turn Locking Slotted Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Push-turn Locking Slotted Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Grommet, Lead Wire Length: 300mm, Surge Suppressor: None, Manual Override: Push-turn Locking Slotted Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: NPT, Port Size: 1, Option: Silencer, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Name Plate and Pressure Gauge in Imperial Units
Body Size: 5000, Thread: N (NPT), Port Size: 10 (1), Option: S (Silencer), Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 5000, Thread: N (NPT), Port Size: 10 (1), Option: S (Silencer), Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)