SMC Corporation of America
Elite Part Number Search
Search Results "C96SD100-600C"

...n Pieces H O W T O O R D E R M Y 1 C R O D L E S S C Y L I N D E R MY1C G T E C H N I C A L SPECIFICATIONS Bore Size (mm) 16 20 25 32 40 50 63 Fluid Filtered, Non-Lubricated Air B O R E S I Z E 16 16mm 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Operation Type Double Acting Type Operating Pressure 0.1 ~ 0.8 MPa / 14.5 ~ 116PSI Proof Pressure 1.2MPa / 174PSI Ambient & Fluid Temp 5 ~ 600C

...n Pieces H O W T O O R D E R M Y 1 C R O D L E S S C Y L I N D E R MY1C G T E C H N I C A L SPECIFICATIONS Bore Size (mm) 16 20 25 32 40 50 63 Fluid Filtered, Non-Lubricated Air B O R E S I Z E 16 16mm 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Operation Type Double Acting Type Operating Pressure 0.1 ~ 0.8 MPa / 14.5 ~ 116PSI Proof Pressure 1.2MPa / 174PSI Ambient & Fluid Temp 5 ~ 600C

/ 40~140F 5~600C / 40~140F Thread R(PT) R(PT) One Touch Fittings One Touch Fittings AN P O R T S I Z E ( S C R E WI N) 01 1/ 8 02 1/ 4 03 3/ 8 04 1/ 2 06 3/ 4 10 1 12 1 1/ 4 14 1 1/ 2 20 2 (A1 only) One Touch C06 6 (B1 only) C08 8 C10 10 C12 12 (A1 only) S Y M B O L S S E R I E S A1 Noise Reduction at 40dB(A) B1 Noise Reduction at 38dB(A) D I M E N S I O N S MODEL (THREAD CONNECTION

This is a legacy product, and replaced byC96SDT63-600C

This is a legacy product, and replaced byCP96SDB63-600C

Load Voltage DC12~24V (Ripple + 10%) Load Current 5~40mA Leak Current 1mA Inner Drop Voltage 5V Switch Output (see Diagram) Present Pressure Present Pressure Set Pressure: ON Set Pressure: ON Indication Lamp ON: Red LED turns on Operating Temperature 0~600C / 32~140F Piping Method 6 reducer Lead Wire Grommet Type Oil-proof Captyre-cord two Wires 2.55, 0.18mm 2, 3m H O W T O O R D E R S

This is a legacy product, and replaced byC96SDB40-600C C95/C96 TIE-ROD CYLINDER. CYL, TIE ROD, ISO, AUTO-SW. ACTUATOR. 40MM C95/CP95 DBL-ACT AUTO-SW. 7.92000 lb. ME.

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 320, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Magnet: None, Mounting: Double Clevis, Bore Size: 100mm, Stroke: 500mm, Rod Boot: -, Rod: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -