Your search for CA2 returned 30 result(s)
There were no hits with the full part number, but there were 17 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended fluid and ambient temperature range provides best performance and longest life.
,xt2S Y G G Aat Rat with_ril l G G 'G Rat FJat~ ri ZPR40g 4D 43 1 8.5 32 42B 160.6 6 8 6.5 , 3.3 ZPR20~ 20 23 1 4 29 39.8 57.6 5 6 6 4 1.7 zPR25~ 25 28 , . 14 29 39B 57.6 5 6 8 , ZPR5O~ (iO 53 1 95 33 m l61.6 6 . 6 75f i 3 .8 , 4 1.8 ZPR32~ 32 35 14.5 29.5 40.3 sal 5 6 8 4.5 2.3 Deep type (mm) "B E I. F '-1: M6 x1 M:U8xt25 y Model C 0 M G I.. G Deep type (mm) H:M5xO.8 H:t.
Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended operating fluid and temperature range provides best performance and longest life.
Magnet: None, Series: A2 (Standard), Mounting: L (Axial Foot), Low Friction: Q (Low Friction), Tube Material: Aluminum Tube, Bore Size: Ø80, Port Thread: TN (NPT), Stroke: 25mm, Low Friction Direction: F (Head Side at Pressure)
Magnet: None, Series: Standard, Mounting: Axial Foot, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø80, Port Thread: NPT, Stroke: 25mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket